- Hein Heidbüchel, Pieter Lioen, Stefaan Foulon, Wim Huybrechts, Joris Ector, Rik Willems, and Hugo Ector.
- Department of Cardiology-Electrophysiology, University Hospital Gasthuisberg, University of Leuven, Herestraat 49, B-3000 Leuven, Belgium. hein.heidbuchel@uz.kuleuven.ac.be
- Europace. 2008 Mar 1; 10 (3): 351-7.
AimsFollow-up of implantable cardioverter defibrillator (ICD) patients, with regular in-office visits every 3-6 months, puts a significant burden on specialized electrophysiology clinics. New technology allows for remote monitoring of device function. We wanted to investigate its potential reliability and to which extent its use can reduce in-office visits.Methods And ResultsWe retrospectively analysed data from 1739 prospectively coded ICD visits in a random set of 169 patients (followed between 2 month and 10.4 year in an academic centre). We defined (i) whether the visit was planned or not, (ii) what were the reasons for unplanned visits, (iii) whether any relevant finding was made, (iv) whether a remote monitoring system with the ability or not to detect pacing threshold would have been able to capture the problem, and (v) what actions were taken. The standard follow-up scheme consisted of in-office visits 1 month after implantation and then every 6 months, unless approaching battery depletion. From the 1739 visits, 1530 were performed according to clinical schedule (88%) and in 1197 of those (78.2%), no relevant finding was made. In 0.52% (n = 8) early post-implant pacing threshold increases would not have been detected by remote monitoring without the ability to determine thresholds (although two patients showed a high impedance). Moreover, in 6% of the planned visits, reprogramming would require a consecutive in-office visit (4%) or hospitalization (2%). Only 175 visits (9.6% of all) were conducted prior to the planned follow-up date due to patient symptoms [another 42 (2.4%) were due to planned surgery or safety warnings]. The proportion of relevant findings during unscheduled visits was significantly higher than during scheduled visits (80.6 vs. 21.8%; P < 0.0001) and a higher proportion of those was arrhythmia- and/or device-related (85.1 vs. 55.3%, P < 0.0001). Reprogramming was required more often (33.1 vs. 4%; P < 0.0001) and hospitalization rate was higher (18.3 vs. 2%; P < 0.0001), so that 51.4% of unscheduled visits would require in-office evaluation. Overall, remote follow-up would correctly exclude device function abnormalities or arrhythmic problems in 1402 (82.2%), identify an arrhythmic problem in 262 (15.3%), correctly identify a device-related problem in 35 (2.1%), but potentially miss an isolated pacing problem in 6 (0.46%). Clinical evaluation would diagnose a relevant clinical problem in the absence of any device interrogation abnormality in 170 patients (10%).ConclusionICD remote monitoring can potentially diagnose >99.5% of arrhythmia- or device-related problems if combined with clinical follow-up by the local general practitioner and/or referring cardiologist. It may provide a way to significantly reduce in-office follow-up visits that are a burden for both hospitals and patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.