- Venkatakrishna Rajajee, Craig A Williamson, Robert J Fontana, Anthony J Courey, and Parag G Patil.
- Department of Neurosurgery, University of Michigan, Taubman Health Care Center 3522, SPC 5338, 1500 East Medical Center Drive, Ann Arbor, MI, 48109-5338, USA. vrajajee@yahoo.com.
- Neurocrit Care. 2018 Oct 1; 29 (2): 280-290.
BackgroundElevated intracranial pressure (ICP) is an important cause of death following acute liver failure (ALF). While invasive ICP monitoring (IICPM) is most accurate, the presence of coagulopathy increases bleeding risk in ALF. Our objective was to evaluate the accuracy of three noninvasive ultrasound-based measures for the detection of concurrent ICP elevation in ALF-optic nerve sheath diameter (ONSD) using optic nerve ultrasound (ONUS); middle cerebral artery pulsatility index (PI) on transcranial Doppler (TCD); and ICP calculated from TCD flow velocities (ICPtcd) using the estimated cerebral perfusion pressure (CPPe) technique.MethodsIn this retrospective study, consecutive ALF patients admitted over a 6-year period who underwent IICPM as well as measurement of ONSD, TCD-PI or ICPtcd were included. ONSD was measured offline by a blinded investigator from deidentified videos. The ability of highest ONSD, TCD-PI, and ICPtcd to detect concurrent invasive ICP > 20 mmHg was assessed using receiver operating characteristic (ROC) curves. The ROC area under the curve (AUC) was calculated with 95% confidence interval (95% CI) and evaluated against the null hypothesis of AUC = 0.5. Noninvasive measures were also evaluated as predictors of in-hospital death.ResultsForty-one ALF patients were admitted during the study period. In total, 27 (66%) underwent IICPM, of these, 23 underwent ONUS and 21 underwent TCD. Eleven out of 23 (48%) patients died (two from intracranial hypertension). Results of ROC analysis for detection of concurrent ICP > 20 mmHg were as follows: ONSD AUC = 0.59 (95% CI 0.37-0.79, p = 0.54); TCD-PI AUC = 0.55 (95% CI 0.34-0.75, p = 0.70); and ICPtcd AUC = 0.90 (0.72-0.98, p < 0.0001). None of the noninvasive measures were significant predictors of death.ConclusionsIn patients with ALF, neither ONSD nor TCD-PI reliably detected concurrent ICP elevation on invasive monitoring. Estimation of ICP (ICPtcd) using the TCD CPPe technique was associated with concurrent ICP elevation. Additional studies of TCD CPPe in larger numbers of ALF patients may prove worthwhile.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.