Scand J Trauma Resus · Jun 2018
Capillary and venous lactate measurements with a handheld device compared to venous blood-gas analysis for emergency patients.
- David Stoll, Erling Englund, Helene Hillborg, Stefan Vedin, and Agneta Larsson.
- Ambulance Services, Sundsvall Hospital, Västernorrland County Council, 851 86, Sundsvall, Sweden. David.stoll@lvn.se.
- Scand J Trauma Resus. 2018 Jun 5; 26 (1): 47.
Background/AimEarly identification of lactate levels may have a large impact on triage classification and assist in identifying critically ill patients. A handheld device provides a rapid and timesaving measurement of lactate levels adapted to work in a prehospital care setting. I.e., the device is small, fast, and easy-to-use. The aim of this study was to evaluate the Accutrend Plus handheld lactate analyzer in comparison to the reference in-hospital method.MethodsPatients triaged as minimum yellow according to the RETTS System (Rapid Emergency Triage and Treatment System) and transported to hospital by ambulance were selected and a written consent to participate was obtained prior to inclusion in the study. Capillary (CAP) and venous (VEN) blood were analyzed with Accutrend Plus (AP). Venous blood samples were analyzed at the local hospital laboratory (GEM premier 4000) within 20 min from sampling. All sampling was conducted by two registered nurses specially trained in prehospital care.Results480 lactate measurements were performed in 160 patients. The mean difference between measurements in capillary blood compared with the reference method was 0.7 mmol/L and for venous blood 0.9 mmol/L. The limits of agreement from the Bland-Altman plot was - 0.9 to + 2.5 mmol/L and and - 0.1 to + 1.9 mmol/L, for CAP and VEN compared with GEM.ConclusionOur results shows low accuracy and low precision with VEN / CAP measurements of lactate compared to reference GEM.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.