    Impact of connector placement and design on bending stiffness of spinal constructs.

    • Jakub Godzik, Nick Hool, Jonathan F Dalton, Alexander C Whiting, Newcomb Anna G U S AGUS Spinal Biomechanics Laboratory, Department of Neurosurgery Research, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoe, Brian P Kelly, and Neil R Crawford.
    • Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona.
    • World Neurosurg. 2019 Jan 1; 121: e89-e95.

    ObjectiveTo evaluate the stability of multiple rod-connector construct designs using a mechanical 4-point bending testing frame.MethodsA mechanical study was used to evaluate the bending stiffness of 3 connectors across 12 different configurations of rod-connector-rod constructs. Stability was evaluated in flexion-extension and lateral bending. Combinations of rods having 1 of 3 diameters (4.0 mm, 5.5 mm, and 6.0 mm) connected by 1 of 3 connector types (parallel open, snap-on, and hinged) were compared. Configurations with single connectors and with double connectors with variable spacing were also compared to simulate revision surgery conditions.ResultsConstructs consisting of 4.0-mm rods connected to 4.0-mm rods were significantly less stiff as the total number of connectors used in a series exceeded 2. When single-connector configurations were compared, parallel open rod connectors demonstrated greater stiffness in flexion-extension than hinged open connectors, whereas hinged open connectors demonstrated greater stiffness in lateral bending. Using double connectors increased stiffness of 4.0- to 4.0-mm rod configurations in flexion-extension and lateral bending, 4.0- to 6.0-mm rod configurations in flexion-extension, and 5.5- to 6.0-mm rod configurations in lateral bending. Spacing the double connectors significantly improved lateral bending stiffness of 4.0- to 4.0-mm and 5.5- to 6.0-mm rod configurations.ConclusionsOur data indicate that the design, number, and placement of rod connectors have a significant impact on the bending stiffness of a surgical construct. Such mechanical data may influence construct design in primary and revision surgeries of the cervical spine and cervicothoracic junction.Copyright © 2018 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.