• Anaesthesia · Nov 2018

    In-vitro analysis of a novel 'add-on' silicone cuff to improve sealing properties of tracheal tubes.

    • G Li Bassi, C Chiurazzi, E Aguilera, C Travierso, D Battaglini, M Yang, A Motos, H Yang, A Meli, D Marti, O T Ranzani, F Blasi, P Pelosi, D Chiumello, and A Torres.
    • Department Hospital Clínic, Thorax Institute, Pneumology Department, and University of Barcelona, Barcelona, Spain.
    • Anaesthesia. 2018 Nov 1; 73 (11): 1372-1381.

    AbstractLeakage of colonised oropharyngeal secretions across the tracheal tube cuff may cause iatrogenic pulmonary infection. We studied a novel 'add-on' cuff, which can be inserted over an existing tracheal tube and advanced into the subglottic region. The physical properties of the novel silicone cuff (BronchoGuard, Ciel Medical, USA) were evaluated in comparison with the Hi-Lo® tracheal tube. In a bench study, we identified saline inflation volumes required to transmit pressures between 15 and 30 cmH2 O against artificial tracheas of 18, 20 and 22 mm internal diameter. We computed cuff compliance, and minimal inflation volume to achieve air sealing during mechanical ventilation. Finally, we compared the leakage flow rate of artificial saliva across the novel cuff. On average, the mean (SD) inflation volumes necessary to transmit tracheal pressures of 15, 20, 25 and 30 cmH2 O were 4.1 (2.2), 4.4 (2.3), 4.6 (2.4) and 4.8 (2.4) ml for the novel cuff and 7.7 (2.5), 8.0 (2.6), 8.4 (2.6) and 8.7 (2.7) ml for the Hi-Lo tube, respectively (p < 0.001). The minimal inflation volumes to achieve air sealing were 3.8 (0.9) and 10.5 (2.1) ml (p < 0.001), which resulted in transmitted tracheal pressures of 8.3 (9.8) and 27.6 (34.8) cmH2 O (p < 0.001). Compliance was 0.026 (0.004) and 0.616 (0.324) ml.cmH2 0-1 , respectively (p < 0.001). Although massive leak was found when the novel cuff transmitted pressures ≤ 20 cmH2 O against the trachea, leakage was avoided with pressures ≥ 25 cmH2 O, owing to optimal contact between the cuff and the tracheal wall. In contrast, the standard cuff consistently leaked irrespective of the pressure. We conclude that the novel cuff has advantageous properties that warrant clinical corroboration.© 2018 Association of Anaesthetists.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…