• Anesthesiology · Apr 2001

    Automated responsiveness test (ART) predicts loss of consciousness and adverse physiologic responses during propofol conscious sedation.

    • A G Doufas, M Bakhshandeh, A R Bjorksten, R Greif, and D I Sessler.
    • Department of Anesthesia and Perioperative Care, University of California-San Francisco, USA.
    • Anesthesiology. 2001 Apr 1; 94 (4): 585-92.

    BackgroundThe authors evaluated a device designed to provide conscious sedation with propofol (propofol-air), or propofol combined with 50% nitrous oxide (N2O; propofol-N2O). An element of this device is the automated responsiveness test (ART), a method for confirming that patients remain conscious. The authors tested the hypotheses that the ART predicts loss of consciousness and that failure to respond to the ART precedes sedation-induced respiratory or hemodynamic toxicity.MethodsThe protocol consisted of sequential 15-min cycles in 20 volunteers. After a 15-min control period, propofol was infused to an initial target effect-site concentration of 0.0 microg/ml with N2O or 1.5 microg/ml with air. Subsequently, the propofol target effect-site concentration was increased by a designated increment (0.25 and 0.5 microg/ml) and the process repeated. This sequence was continued until loss of consciousness, as defined by an Observer's Assessment of Alertness/Sedation (OAA/S) score of 10/20 or less, or until an adverse physiologic event was detected.ResultsThe OAA/S score at which only 50% of the volunteers were able to respond to the ART (P50) during propofol-N2O was 11.1 of 20 (95% confidence interval [CI]: 10.6-11.8); the analogous P50 was 11.8 of 20 (95% CI: 11.4-12.3) with propofol-air. Failure to respond to the ART occurred at a plasma propofol concentration of 0.7 +/- 0.6 microg/ml with propofol-N2O and 1.6 +/- 0.6 microg/ml with propofol-air, whereas loss of consciousness occurred at 1.2 +/- 0.8 microg/ml and 1.9 +/- 0.7 microg/ml, respectively. There were no false-normal ART responses.ConclusionThe ART can guide individual titration of propofol because failure to respond to responsiveness testing precedes loss of consciousness and is not susceptible to false-normal responses. The use of N2O with propofol for conscious sedation decreases the predictive accuracy of the ART.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…