-
- Francesca Bagnato, Simon Hametner, Giulia Franco, Siddharama Pawate, Subramaniam Sriram, Hans Lassmann, John Gore, Seth E Smith, and Richard Dortch.
- Department of Neurology, Neuro-Immunology Division/Neuro-Imaging Unit, Vanderbilt University Medical Center, Nashville, TN.
- J Neuroimaging. 2018 Jul 1; 28 (4): 380-388.
Background And PurposeAn imaging biomarker of myelin integrity is an unmet need in multiple sclerosis (MS). Selective inversion recovery (SIR) quantitative magnetization transfer imaging (qMT) provides assays of myelin content in the human brain. We previously translated the SIR method to 7T and incorporated a rapid turbo field echo (TFE) readout for whole-brain imaging within clinically acceptable scan times. We herein provide histological validation and test in vivo feasibility and applicability of the SIR-TFE protocol in MS.MethodsClinical (T1 - and T2 -weighted) and SIR-TFE MRI scans were performed at 7T in a postmortem MS brain and MRI data were acquired in 10 MS patients and 14 heathy volunteers in vivo. The following parameters were estimated from SIR data: the macromolecular-to-free water pool-size-ratio (PSR), the spin-lattice relaxation rate of water (R1f ), and the MT exchange rate (kmf ). Differences in SIR parameters across tissue types, eg, white matter lesions (WM-Ls) and normal appearing WM (NAWM) in patients, and normal white matter (NWM) in heathy volunteers were evaluated. Associations between SIR parameters and disability scores were assessed.ResultsFor postmortem scans, correspondence was observed between WM-Ls and NAWM from histology and PSR/R1f values. In vivo differences were detected for PSR, R1f , and kmf between WM-Ls and NWM (P ≤ .041). Associations were seen between WM-Ls/ NAWM PSR and disability scores (r ≤ -.671, P ≤ .048).ConclusionsSIR-qMT at 7T provides sensitive, quantitative measures of myelin integrity for clinical and research applications.Copyright © 2018 by the American Society of Neuroimaging.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.