• Resuscitation · Jan 2019

    Towards a Non-Invasive Cardiac Arrest Monitor: an in vivo pilot study.

    • John C Kucewicz, David D Salcido, Adeyinka A Adedipe, Kenneth Truong, Graham Nichol, and Pierre D Mourad.
    • Applied Physics Laboratory, University of Washington, Seattle, WA, United States.
    • Resuscitation. 2019 Jan 1; 134: 76-80.

    IntroductionHemodynamic-guided cardiopulmonary resuscitation (HGCPR) achieves better outcomes than standard resuscitation. Currently, HGCPR requires an invasive procedure, infeasible during resuscitation. Non-invasive measures of blood flow could provide useful hemodynamic guidance to rescuers.ObjectiveWe describe initial efforts to develop a device that detects, analyzes, and measures the velocity of carotid artery blood flow (CABF) towards the brain at pre-arrest baseline ('baseline') and during cardiopulmonary resuscitation, here tested in a swine model of cardiac arrest (CA). A key element of that device consists of non-imaging diagnostic ultrasound, due to its simplicity and small form factor, hence potential for deployment during HGCPR in a bandage placed on the neck.MethodsSixteen mixed-breed domestic swine were sedated, anesthetized and paralyzed, followed by endotracheal intubation and mechanical ventilation. Cardiac arrest was induced with a 3-s 100 mA transthoracic shock or bolus of fentanyl, after which all animals received mechanical CPR. A non-imaging ultrasound probe was manually applied to the neck over the carotid artery to capture CABF during baseline, as verified with diagnostic ultrasound imaging, and during mechanical resuscitation.ResultsWe successfully collected CABF measurements at baseline in 14/16 swine and during attempted resuscitation with mechanical chest compression in 5/16 swine. Signal characteristics include peak blood flow both towards (90.4 +/-20.4 cm/s) and away from the brain (-44.2 +/-31.8 cm/s) during resuscitation, each larger than flow towards (41.7+/-14.8 cm/s) and away from brain (-3.0 +/-7.8 cm/s) during baseline.ConclusionMeasurement of CABF before and during CPR in swine with a non-imaging ultrasound probe is feasible before CA and informative when achieved during CPR. For example, observations of reverse flow within the carotid artery during CPR merits further study for its prevalence and effect on resuscitation outcomes. Also, tissue motion represents a significant obstacle for CABF measurement during CPR. Additional work will determine the feasibility and utility of non-imaging ultrasound measurements of CABF during resuscitation.Copyright © 2018 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…