• Cochrane Db Syst Rev · Aug 2018

    Review Meta Analysis

    Endovascular coiling versus neurosurgical clipping for people with aneurysmal subarachnoid haemorrhage.

    • Antti Lindgren, Mervyn DI Vergouwen, Irene van der Schaaf, Ale Algra, Marieke Wermer, Mike J Clarke, and Gabriel Je Rinkel.
    • Department of Neurosurgery, Kuopio University Hospital, Puijonlaaksontie 2, Kuopio, Kuopio, Finland, 70029.
    • Cochrane Db Syst Rev. 2018 Aug 15; 8: CD003085.

    BackgroundAround 30% of people who are admitted to hospital with aneurysmal subarachnoid haemorrhage (SAH) will rebleed in the initial month after the haemorrhage if the aneurysm is not treated. The two most commonly used methods to occlude the aneurysm for prevention of rebleeding are microsurgical clipping of the neck of the aneurysm and occlusion of the lumen of the aneurysm by means of endovascular coiling. This is an update of a systematic review that was previously published in 2005.ObjectivesTo compare the effects of endovascular coiling versus neurosurgical clipping in people with aneurysmal SAH on poor outcome, rebleeding, neurological deficit, and treatment complications.Search MethodsWe searched the Cochrane Stroke Group Trials Register (March 2018). In addition, we searched CENTRAL (2018, Issue 2), MEDLINE (1966 to March 2018), Embase (1980 to March 2018), US National Institutes of Health Ongoing Trials Register (March 2018), and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (last searched March 2018). We also contacted trialists.Selection CriteriaWe included randomised trials comparing endovascular coiling with neurosurgical clipping in people with SAH from a ruptured aneurysm.Data Collection And AnalysisTwo review authors independently extracted data, and assessed trial quality and risk of bias using the GRADE approach. We contacted trialists to obtain missing information. We defined poor outcome as death or dependence in daily activities (modified Rankin scale 3 to 6 or Glasgow Outcome Scale (GOS) 1 to 3). In the special worst-case scenario analysis, we assumed all participants in the group with better outcome with missing follow-up information had a poor outcome and those in the other group with missing data a good outcome.Main ResultsWe included four randomised trials involving 2458 participants (range per trial: 20 to 2143 participants). Evidence is mostly based on the largest trial. Most participants were in good clinical condition and had an aneurysm on the anterior circulation. None of the included trials was at low risk of bias in all domains. One trial was at unclear risk in one domain, two trials at unclear risk in three domains, and one trial at high risk in one domain.After one year of follow-up, 24% of participants randomised to endovascular treatment and 32% of participants randomised to the surgical treatment group had poor functional outcome. The risk ratio (RR) of poor outcome (death or dependency) for endovascular coiling versus neurosurgical clipping was 0.77 (95% confidence interval (CI) 0.67 to 0.87; 4 trials, 2429 participants, moderate-quality evidence), and the absolute risk reduction was 7% (95% CI 4% to 11%). In the worst-case scenario analysis for poor outcome, the RR for endovascular coiling versus neurosurgical clipping was 0.80 (95% CI 0.71 to 0.91), and the absolute risk reduction was 6% (95% CI 2% to 10%). The RR of death at 12 months was 0.80 (95% CI 0.63 to 1.02; 4 trials, 2429 participants, moderate-quality evidence). In a subgroup analysis of participants with an anterior circulation aneurysm, the RR of poor outcome was 0.78 (95% CI 0.68 to 0.90; 2 trials, 2157 participants, moderate-quality evidence), and the absolute risk decrease was 7% (95% CI 3% to 10%). In subgroup analysis of those with a posterior circulation aneurysm, the RR was 0.41 (95% CI 0.19 to 0.92; 2 trials, 69 participants, low-quality evidence), and the absolute decrease in risk was 27% (95% CI 6% to 48%). At five years, 28% of participants randomised to endovascular treatment and 32% of participants randomised to surgical treatment had poor functional outcome. The RR of poor outcome for endovascular coiling versus neurosurgical clipping was 0.87 (95% CI 0.75 to 1.01, 1 trial, 1724 participants, low-quality evidence). At 10 years, 35% participants allocated to endovascular and 43% participants allocated to surgical treatment had poor functional outcome. At 10 years RR of poor outcome for endovascular coiling versus neurosurgical clipping was 0.81 (95% CI 0.70 to 0.92; 1 trial, 1316 participants, low-quality evidence). The RR of delayed cerebral ischaemia at two to three months for endovascular coiling versus neurosurgical clipping was 0.84 (95% CI 0.74 to 0.96; 4 trials, 2450 participants, moderate-quality evidence). The RR of rebleeding for endovascular coiling versus neurosurgical clipping was 1.83 (95% CI 1.04 to 3.23; 4 trials, 2458 participants, high-quality evidence) at one year, and 2.69 (95% CI 1.50 to 4.81; 1 trial, 1323 participants, low-quality evidence) at 10 years. The RR of complications from intervention for endovascular coiling versus neurosurgical clipping was 1.05 (95% CI 0.44 to 2.53; 2 trials, 129 participants, low-quality evidence).Authors' ConclusionsThe evidence in this systematic review comes mainly from one large trial, and long-term follow-up is available only for a subgroup of participants within that trial. For people in good clinical condition with ruptured aneurysms of either the anterior or posterior circulation the data from randomised trials show that, if the aneurysm is considered suitable for both neurosurgical clipping and endovascular coiling, coiling is associated with a better outcome. There is no reliable trial evidence that can be used directly to guide treatment in people with a poor clinical condition.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.