• Respiratory care · Aug 2018

    Incidence of Hypocapnia, Hypercapnia, and Acidosis and the Associated Risk of Adverse Events in Preterm Neonates.

    • Melissa K Brown, Deborah M Poeltler, Kasim O Hassen, Danielle V Lazarus, Vanessa K Brown, Jeremiah J Stout, Wade D Rich, and Anup C Katheria.
    • Neonatal Research Institute at Sharp Mary Birch Hospital for Women and Newborns, San Diego, California. melissa.brown@sharp.com.
    • Respir Care. 2018 Aug 1; 63 (8): 943-949.

    BackgroundPermissive hypercapnia is a lung-protection strategy. We sought to review our current clinical practice for the range of permissive hypercapnia and identify the relationship between PaCO2 and pH and adverse outcomes.MethodsA secondary analysis of a delayed cord-clamping clinical trial was performed on all arterial blood gas tests in the first 72 h in infants < 32 weeks gestational age. All arterial blood gas values were categorized into a clinical range to determine the percent likelihood of occurring in the total sample. The univariate and multivariate relationships of severe adverse events and the time-weighted PaCO2 , fluctuation of PaCO2 , maximal and minimal PaCO2 , base excess, and pH were assessed.Results147 infants with birthweight of 1,206 ± 395 g and gestational age of 28 ± 2 weeks were included. Of the 1,316 total samples, < 2% had hypocapnia (PaCO2 <30 mm Hg), 47% were normocapnic (PaCO2 35-45 mm Hg), 26.5% had mild hypercapnia (PaCO2 45-55 mm Hg), 13% had moderate hypercapnia (PaCO2 55-65 mm Hg), and 6.5% had severe hypercapnia (PaCO2 ≥ 65 mm Hg). There were no adverse events associated with hypocapnia. Subjects with death/severe intraventricular hemorrhage had a higher mean PaCO2 of 52.3 versus 44.7 (odds ratio [OR] 1.16, 95% CI 1.04-1.29, P = .006), higher variability of PaCO2 with a standard deviation of 12.6 versus 7.8 (OR 1.15, 95% CI 1.03-1.27, P = .01), and a lower minimum pH of 7.03 versus 7.23 (OR 0, 95% CI 0-0.06, P = .003). There was no significant difference in any variables in subjects who developed other adverse events.ConclusionThe routine targeting of higher than normal PaCO2 goals may lead to a low incidence of hypocapnia and associated adverse events. Hypercapnia is common, and moderate hypercapnia may increase the risk of neurologic injury and provide little pulmonary benefit.Copyright © 2018 by Daedalus Enterprises.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…