• Respiratory care · Dec 2018

    Randomized Controlled Trial

    Effects of Mechanical Insufflation-Exsufflation on Airway Mucus Clearance Among Mechanically Ventilated ICU Subjects.

    • Márcio Luiz Ferreira de Camillis, Augusto Savi, Goulart Rosa Regis R Intensive Care Unit, Hospital Moinhos de Vento, Porto Alegre, Brazil., Mariana Figueiredo, Ricardo Wickert, Borges Luis Guilherme Alegretti LGA Intensive Care Unit, Hospital Moinhos de Vento, Porto Alegre, Brazil., Lucas Galant, and Cassiano Teixeira.
    • Intensive Care Unit, Hospital Moinhos de Vento, Porto Alegre, Brazil.
    • Respir Care. 2018 Dec 1; 63 (12): 1471-1477.

    BackgroundFew studies have evaluated the effects of mechanical insufflation-exsufflation (MI-E) in subjects on mechanical ventilation. Therefore, this study aimed to evaluate the effectiveness of MI-E on airway mucus clearance among mechanically ventilated ICU subjects.MethodsA randomized, parallel-group, open-label trial was conducted between June and November 2017 in a single, mixed ICU. Adult ICU subjects receiving mechanical ventilation for > 24 h with stable ventilatory and hemodynamic status were randomized to receive either standard respiratory physiotherapy alone (control group) or respiratory physiotherapy by using an MI-E device (intervention group). The primary outcome was the weight of aspirated airway mucus after study interventions. Secondary outcomes included variation in static lung compliance (ΔCL), airway resistance (ΔRaw), work of breathing (ΔWOB) in relation to the pre-intervention period, and hemodynamic and ventilator complications during the procedures.ResultsThere were 90 subjects in each group. The mean ± SD weight of the aspirated airway mucus was higher in the intervention group than in the control group (2.42 ± 2.32 g vs 1.35 ± 1.56 g, P < .001). The ΔCL values in the intervention group were higher than those in the control group (1.76 ± 4.90 mL/cm H2O vs -0.57 ± 4.85 mL/cm H2O, P = .001). The ΔRaw and ΔWOB values were similar between the groups. No hemodynamic or ventilatory complications were observed.ConclusionsAmong the general ICU subjects receiving mechanical ventilation, use of an MI-E device during respiratory physiotherapy resulted in a larger amount of airway mucus clearance than respiratory physiotherapy alone. (ClinicalTrials.gov registration NCT03178565.).Copyright © 2018 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.