Paediatric anaesthesia · Dec 2018
Performance of blow-by methods in delivering oxygen to pediatric patients during transport: A laboratory study.
- Barends Clemens R M CRM 0000-0002-1216-0576 Department of Anesthesiology, University of Groningen and University Medical Center Groningen, Groningen, , Pembegul Yavuz, Bouwe Molenbuur, and Anthony R Absalom.
- Department of Anesthesiology, University of Groningen and University Medical Center Groningen, Groningen, The Netherland.
- Paediatr Anaesth. 2018 Dec 1; 28 (12): 1142-1147.
BackgroundProviding supplemental oxygen with a blow-by method is used to provide additional oxygen to patients who will not tolerate an oxygen delivery device in direct contact with their face. Blow-by methods are often improvised from parts of standard equipment. The performance is very dependent on the distance to the face and the direction of the gas flow. Blow-by methods are used by anesthetists during transport but their performance in delivering supplemental oxygen has only been tested in static situations. The aim of this nonclinical study was to determine the performance of different blow-by methods in the delivery of additional oxygen to pediatric patients during transport.MethodsA manikin of a child with a facemask of appropriate size was transported along a 60 m corridor from the operating theater to the PACU. Oxygen delivery to the face of the manikin was measured during transport. Six blow-by methods were tested with oxygen flows of 3, 6, and 10 L/min and with the facemask at 0 cm from the face and at 5 cm from the face. The outcome parameter was: blow-by method reaching and maintaining an FiO2 >50% during transport from the pediatric operating theater to the PACU.ResultsAt 0 cm from the face, five out of six blow-by methods maintained a FiO2 >50% with all three flow rates. At 5 cm only two of the blow-by methods were able to maintain an FiO2 >50% and this only at flow rates of 10 L/min. All other blow-by methods provided lower FiO2 s; in three, the FiO2 decreased to values only marginally above 21%. The decrease in FiO2 typically started within 6-12 m from the start of the transport.ConclusionIt is concluded that the ability of blow-by methods to deliver a FiO2 >50% depends on the method used and distance from the face.© 2018 The Authors Pediatric Anesthesia Published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.