- Killian Patton-Rivera, James Beck, Kenmond Fung, Christine Chan, Matthew Beck, Hiroo Takayama, and Koji Takeda.
- New York Presbyterian-Columbia University Medical Center, New York, NY, USA.
- Perfusion. 2018 Nov 1; 33 (8): 618-623.
BackgroundPatients requiring V-A ECMO who receive femoral cannulation have an associated risk of distal, lower-limb hypoperfusion and ischemia of the cannulated leg. This pilot study evaluated the usefulness of non-invasive lower-limb oximetry, using near-infrared reflectance spectroscopy (NIRS) to detect limb ischemia.MethodsBetween June 2016 and January 2017, 25 patients receiving femoral V-A ECMO were continuously monitored using the CASMED Fore-Sight Elite (CAS Medical Systems Inc., Branford, CT) tissue oximeter. A retrospective pilot study was conducted to review the correlation between NIRS tissue saturations (StO2) and clinical indications of limb ischemia. Patients were monitored for StO2s less than 50% for more than four minutes or StO2 differentials between the cannulated and non-cannulated legs greater than 15%.ResultsTwenty-five patients (age 22-78) were monitored with NIRS. Six patients had clinical indications of lower-limb ischemia: cold limb, mottled skin and pulseless Doppler ultrasound. All six patients had StO2s below 50% that persisted for longer than four minutes. Of the 25 patients, one patient had a false-positive indication of hypoperfusion with StO2 below 50% for more than four minutes due to a venous saturation below 30%. Another patient had a false-positive pulseless Doppler ultrasound caused by high doses of pressor support. The StO2 was greater than 60%, which confirmed the clinical determination of adequate perfusion. Five patients had StO2s below 50% for less than four minutes and none of these patients had clinical indications of lower-limb hypoperfusion. All patients with cannula-related obstruction of flow to the distal portion of the leg had StO2 differentials greater than 15%. No patients without cannula-related obstruction to flow had StO2 differentials greater than 15%.ConclusionAdvancements in NIRS technology seem to have improved its accuracy for continuous, non-invasive monitoring of regional tissue and may provide clinicians with an additional metric to protect the distal portion of the cannulated leg.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.