• Anesthesia and analgesia · Jan 2019

    Randomized Controlled Trial

    Diagnostic Accuracy of Point-of-Care Gastric Ultrasound.

    • Richelle Kruisselbrink, Angineh Gharapetian, Luis E Chaparro, Noam Ami, Dustin Richler, Chan Vincent W S VWS From the Department of Anesthesia and Pain Management, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada. , and Anahi Perlas.
    • From the Department of Anesthesia and Pain Management, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
    • Anesth. Analg. 2019 Jan 1; 128 (1): 89-95.

    BackgroundPulmonary aspiration of gastric contents is associated with significant perioperative morbidity and mortality. Previous studies have investigated the validity, reliability, and possible clinical impact of gastric ultrasound for the assessment of gastric content at the bedside. In the present study, we examined the accuracy (evaluated as sensitivity, specificity, and likelihood ratios) of point-of-care gastric ultrasound to detect a "full stomach" in a simulated scenario of clinical equipoise.MethodsAfter a minimum fasting period of 8 hours, 40 healthy volunteers were randomized in a 1:1 ratio to either remain fasted or ingest a standardized quantity of clear fluid or solid. Each subject was randomized twice on 2 independent study sessions at least 24 hours apart. A gastric ultrasound examination was performed by a blinded sonographer following a standardized scanning protocol. Using a combination of qualitative and quantitative findings, the result was summarized in a dichotomous manner as positive (any solid or >1.5 mL/kg of clear fluid) or negative (no solid and ≤1.5 mL/kg of clear fluid) for full stomach.ResultsData from 80 study sessions were analyzed. In this simulated clinical scenario with a pretest probability of 50%, point-of-care gastric ultrasound had a sensitivity of 1.0 (95% confidence interval [CI], 0.925-1.0), a specificity of 0.975 (95% CI, 0.95-1.0), a positive likelihood ratio of 40.0 (95% CI, 10.33-∞), a negative likelihood ratio of 0 (95% CI, 0-0.072), a positive predictive value of 0.976 (95% CI, 0.878-1.0), and a negative predictive value of 1.0 (95% CI, 0.92-1.0).ConclusionsOur results suggest that bedside gastric ultrasound is highly sensitive and specific to detect or rule out a full stomach in clinical scenarios in which the presence of gastric content is uncertain.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.