• Spine · Sep 2018

    Stiffness Matters: Part I-The Effects of Plate Stiffness on the Biomechanics of ACDF In Vitro.

    • Joshua M Peterson, Carolyn Chlebek, Ashley M Clough, Alexandra K Wells, and Eric H Ledet.
    • Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy.
    • Spine. 2018 Sep 15; 43 (18): E1061-E1068.

    Study DesignIn vitro biomechanical testing of human cadaveric cervical and goat cervical motion segments.ObjectiveThe aim of this study was to measure the effects of plate stiffness on load-sharing, instantaneous axis of rotation (IAR), and posterior element loading after anterior cervical discectomy and fusion (ACDF).Summary Of Background DataACDF is intended to create an environment, which facilitates sufficient stability and biomechanical conditions to promote bone formation. The relationship between cervical plate stiffness, load-sharing, and the IAR is complex. The ideal cervical plate is sufficiently stiff to limit interbody motion but is compliant enough to facilitate load-sharing rather than stress-shielding.MethodsAnterior cervical plates of distinct bending stiffnesses were applied to human and goat cervical motion segments following ACDF. A validated custom force-sensing interbody implant was placed in the disc space to measure load-sharing in the spine. Interbody loads, posterior element strain, and the IAR were measured during flexion/extension for each plate.ResultsLoad-sharing in the interbody space, posterior element strain, and the location of the IAR were all significantly affected by plate stiffness. More compliant plates resulted in more load sharing, less posterior element strain, and a more dorsally located IAR relative to stiffer plates.ConclusionA more compliant plate fosters more consistent load-sharing through the entire range of flexion/extension, which may promote faster bone formation and better fusion. A more compliant plate causes less posterior element strain, which may reduce facet joint loads and in turn reduce facet joint arthrosis. An ideal plate may be one that is stiff enough to minimize interbody motion and yet compliant enough to allow consistent load-sharing and minimal increase in posterior element strain.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.