• Knee Surg Sports Traumatol Arthrosc · Feb 2018

    ACL suturing using dynamic intraligamentary stabilisation showing good clinical outcome but a high reoperation rate: a retrospective independent study.

    • Martin Meister, Jonathan Koch, Felix Amsler, Markus P Arnold, and Michael T Hirschmann.
    • Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland.
    • Knee Surg Sports Traumatol Arthrosc. 2018 Feb 1; 26 (2): 655-659.

    PurposeMost of the clinical outcome studies dealing with ACL repair are from the developer's perspective. It is a fact that these developer-initiated studies tend to interpret the results rather in favour than against their developed technique or product. Hence, it was the purpose of the present independent investigator-initiated study to investigate the clinical and radiological outcomes as well as failure rate of patients who underwent an ACL suture using dynamic intraligamentary stabilisation device in a specialised independent knee clinic.MethodsA retrospective study was performed on prospectively collected data of 26 patients (28 ± 9 years, range 18-50 years; male/female = 17:9) who underwent biologically augmented ACL suture using dynamic intraligamentary stabilisation. Mean time from ACL injury was 15 ± 5 days (range 4-25 days). In addition, in seven (27%) patients a medial meniscus refixation and in four (15%) patients a lateral meniscus refixation was done for associated meniscal lesions. All patients were clinically and radiologically followed up at 6 weeks, 3 and 12 months after ACL surgery using the Tegner and Lysholm score as well as IKDC score. Adverse events such as ACL failure, arthrofibrosis, pain > 3 on a visual analogue scale as well as the need and type of revision surgery were noted.ResultsFour patients (15%) suffered from an ACL retear due to another adequate trauma during follow-up time. In six patients (23%), an arthrofibrosis (extension deficit of > 10° or flexion deficit > 20°) was noted. In five of those six patients, an arthroscopic arthrolysis was performed. Three patients also complained about pain VAS > 3. In nine (35%) patients, superfluous ACL scar tissue and the DIS device including the polyethylene suture and the DIS screw were removed, and in another two (8%) patients, the DIS screw only was removed. In two patients, a partial meniscectomy was performed due to a non-healed meniscal suture. The median Tegner score was 8 (range 6-10) before injury and 7 (range 3-10) at last follow-up (p < 0.001). The mean Lysholm score before surgery was 28 ± 14 and 94 ± 11 at last follow-up (p < 0.001). At last follow-up, 14 patients (66%) showed a normal total IKDC score (A) and 4 patients (19%) were nearly normal (B) and 2 patients (10%) were slightly abnormal (C) and one patient (5%) was entirely abnormal (p < 0.001).ConclusionACL suturing using the dynamic intraligamentary stabilisation device showed satisfying clinical results at 12-month follow-up. However, a retear rate of 15% and a reoperation rate of 35% due to retear or arthrofibrosis appear rather high. These results highlight the importance of adequate patient selection and the delicacy of the surgical procedure.Level Of EvidenceRetrospective case series, Level IV.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.