Scand J Trauma Resus · Dec 2018
Randomized Controlled TrialComparison of a novel, endoscopic chest tube insertion technique versus the standard, open technique performed by novice users in a human cadaver model: a randomized, crossover, assessor-blinded study.
- Byron C Drumheller, Anthony Basel, Sakib Adnan, Joseph Rabin, Jason D Pasley, Jason Brocker, and Samuel M Galvagno.
- Program in Trauma, Department of Surgery, R Adams Cowley Shock Trauma Center, University of Maryland School of Medicine, 22 South Greene Street, Baltimore, MD, 21201, USA. byron.drumheller@gmail.com.
- Scand J Trauma Resus. 2018 Dec 27; 26 (1): 110.
BackgroundThe technique of tube thoracostomy has been standardized for years without significant updates. Alternative procedural methods may be beneficial in certain prehospital and inpatient environments with limited resources. We sought to compare the efficacy of chest tube insertion using a novel, endoscopic device (The Reactor™) to standard, open tube thoracostomy.MethodsNovice users were randomly assigned to pre-specified sequences of six chest tube insertions performed on a human cadaver model in a crossover design, alternating between the Reactor™ and standard technique. All subjects received standardized training in both procedures prior to randomization. Insertion site, which was randomly assigned within each cadaver's hemithorax, was marked by the investigators; study techniques began with skin incision and ended with tube insertion. Adequacy of tube placement (intrapleural, unkinked, not in fissure) and incision length were recorded by investigators blinded to procedural technique. Insertion time and user-rated difficulty were documented in an unblinded fashion. After completing the study, participants rated various aspects of use of the Reactor™ compared to the standard technique in a survey evaluation.ResultsSixteen subjects were enrolled (7 medical students, 9 paramedics) and performed 92 chest tube insertions (n = 46 Reactor™, n = 46 standard). The Reactor™ was associated with less frequent appropriate tube positioning (41.3% vs. 73.9%, P = 0.0029), a faster median insertion time (47.3 s, interquartile range 38-63.1 vs. 76.9 s, interquartile range 55.3-106.9, P < 0.0001) and shorter median incision length (28 mm, interquartile range 23-30 vs. 32 mm, interquartile range 26-40, P = 0.0034) compared to the standard technique. Using a 10-point Likert scale (1-easiest, 10-hardest) participants rated the ease of use of the Reactor™ no different from the standard method (3.8 ± 1.9 vs. 4.7 ± 1.9, P = 0.024). The Reactor™ received generally favorable scores for all parameters on the post-participation survey.ConclusionsIn this randomized, assessor-blinded, crossover human cadaver study, chest tube insertion using the Reactor™ device resulted in faster insertion time and shorter incision length, but less frequent appropriate tube placement compared with the standard technique. Additional studies are needed to evaluate the efficacy, safety and potential advantages of this novel device.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.