• J. Thorac. Cardiovasc. Surg. · Feb 2019

    Impact of patient-specific morphologies on sinus flow stasis in transcatheter aortic valve replacement: An in vitro study.

    • Hoda Hatoum, Jennifer Dollery, Scott M Lilly, Juan Crestanello, and DasiLakshmi PrasadLPDepartment of Biomedical Engineering, The Ohio State University, Columbus, Ohio; Division of Cardiac Surgery, Department of Surgery, The Ohio State University, Columbus, Ohio. Electronic address: lakshmi.dasi@osumc.edu..
    • Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio.
    • J. Thorac. Cardiovasc. Surg. 2019 Feb 1; 157 (2): 540549540-549.

    ObjectiveThe goal of this study is to evaluate how sinus flow patterns after transcatheter aortic valve replacement in realistic representative patient roots vary. Sinus flow can affect transcatheter aortic valve operation and likely leaflet thrombosis occurrence due to stasis and poor washout. How the interaction between transcatheter aortic valve and representative patient aortic roots affects sinus hemodynamics is important to establish for future individualization of transcatheter aortic valve replacement therapy.MethodsTwo representative patient aortic roots were selected, segmented and 3-dimensional printed followed by deployment of Medtronic CoreValve (Medtronic Inc, Irvine, Calif) and Edwards SAPIEN (Edwards Lifesciences, Irvine Calif) transcatheter aortic valves. Sinus hemodynamics were assessed in vitro using high spatio-temporal resolution particle-image-velocimetry. Detailed sinus vortex tracking, shear stress probability density functions, and sinus washout were evaluated and assessed as a function of valve type and representative patient morphology as independent case studies.ResultsPeak velocity in the sinus with SAPIEN valve was approximately 3 times higher than with CoreValve for both models (0.30 ± 0.02 m/s and 0.34 ± 0.041 m/s vs 0.13 ± 0.01 m/s and 0.10 ± 0.02 m/s) (P < .01). Between representative patient models, vorticity magnitudes were significantly different (75 ± 1.1 s-1, 77 ± 3.2 s-1, 109 ± 2.3 s-1, and 250 ± 4.1 s-1) (P < .01) regardless of valve type. Sinus blood washout characteristic as a function of cardiac cycles was strongly both patient related and valve specific. Fluid dynamics favored shear stresses and washout characteristics due to a smaller sinus and sinotubular junction, further amplified by the SAPIEN valve.ConclusionsSinus flow dynamics are highly sensitive to aortic root characteristics and transcatheter aortic valve aortic root interaction. Differences in sinus-flow washout and stasis regions between representative patient models may be reflected in different risks of leaflet thrombosis or valve degeneration.Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.