    Head-to-head comparison of two continuous glucose monitoring systems on a cardio-surgical ICU.

    • M A Punke, C Decker, M Petzoldt, D A Reuter, K H Wodack, H Reichenspurner, M Kubik, and S Kluge.
    • Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, Hamburg-Eppendorf University Medical Center, Martinistraße 52, 20246, Hamburg, Germany. punke@uke.de.
    • J Clin Monit Comput. 2019 Oct 1; 33 (5): 895-901.

    AbstractIn critical illness hypo-and hyperglycemia have a negative influence on patient outcome. Continuous glucose monitoring (CGM) could help in early detection of hypo-and hyperglycemia. A requirement for these new methods is an acceptable accuracy and precision in clinical practice. In this pilot study we prospectively evaluated the accuracy and precision of two CGM sensors (subcutaneous sensor: Sentrino®, Medtronic and intravasal sensor: Glucoclear®, Edwards) in 20 patients on a cardio-surgical ICU in a head to head comparison. CGM data were recorded for up to 48 h and values were compared with blood-gas-analysis (BGA) values, analysed with Bland-Altman-plots and color-coded surveillance error-grids. Shown are means ± standard deviations. In total 270/255 intravasal/subcutaneous pairs with BGA-values were analysed. The average runtime of the sensors was 28.4 ± 6.4 h. Correlation with BGA values yielded a correlation coefficient of 0.76 (subcutaneous sensor) and 0.92 (intravasal sensor). The Bland Altman Plots revealed an accuracy of 2.5 mg/dl, and a precision of + 43.0 mg/dl to - 38.0 mg/dl (subcutaneous sensor) and an accuracy of - 6.0 mg/dl, and a precision of + 12.4 mg/dl to - 24.4 mg/dl (intravasal sensor). No severe hypoglycemic event, defined as BG level below 40 mg/dl, occurred during treatment. Both sensors showed good accuracy in comparison to the BGA values, however they differ regarding precision, which in case of the subcutaneous sensor is considerable high.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.