    Force Testing of Explanted Magnetically Controlled Growing Rods.

    • Rushton Paul R P PRP Great North Children's Hospital, Royal Victoria Infirmary, Newcastle upon Tyne, UK., Simon L Smith, Liam Forbes, Andrew J Bowey, Michael J Gibson, and Thomas J Joyce.
    • Great North Children's Hospital, Royal Victoria Infirmary, Newcastle upon Tyne, UK.
    • Spine. 2019 Feb 15; 44 (4): 233-239.

    Study DesignLaboratory analysis of explanted MAGnetic Expansion Control (MAGEC) growing rods.ObjectiveThe aim of this study was to measure the force produced by explanted MAGEC rods compared with new rods and assess the influence of clinical variables.Summary Of Background DataMAGEC rods are increasingly used in early-onset scoliosis. Some data are available describing the structure of explanted MAGEC rods, but to date, no study has assessed their function.MethodsExplanted MAGEC rods were received from seven UK and one Danish center. The force produced by explanted rods on activation with the external remote controller was measured using a dedicated jig. Forces were compared with two unused rods as well as the manufacturer's defined standard (42 Ibf). Clinical variables were collected from contributing centers where possible and correlated with the force measurements.ResultsForty-five MAGEC rods from 25 cases were received for analysis. The mean age at insertion was 8.6 years and rods were in vivo for a mean of 2.7 years in predominantly dual rod constructs. Two unused MAGEC rods produced a mean force of 45.3 (0.25) and 50.2 (1.4) Ibf, above the manufacturer's stated standard. Of the 45 explanted rods, 10 (22%) produced force greater or equal to manufacturer's standard, mean 46.7 (2.7) Ibf. Six rods (13%) produced some force but less than the manufacturer's standard, mean 34.8 (3.6) Ibf. Twenty-nine rods (64%) produced no force. The duration the rods were in vivo was significantly negatively correlated with the force produced on testing (r = -0.63, P < 0.005). Of the 12 rods implanted longer than 38 months, none produced any force.ConclusionThis is the first study of the force, and hence likely function, of explanted MAGEC rods. The majority of explanted rods produced no force, while others produced reduced force. These findings raise questions regarding the longevity of the implant and further clinical outcome studies are recommended.Level Of Evidence4.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.