-
- Piergiorgio Lochner, Stefanie Behnke, Klaus Fassbender, Anika Andrejewski, Sophia Knodel, Antonio Siniscalchi, Klaus-V Jenderka, and Robert Lemor.
- Department of Neurology, Saarland University Medical Center, Homburg, Germany.
- J Neuroimaging. 2019 Jan 1; 29 (1): 34-41.
Background And PurposeOptic nerve sheath diameter (ONSD) is used for the estimation of intracranial pressure (ICP). But there are still doubts about the quality of the images and the lateral resolution. Our aim is to investigate the system suitability and best lateral resolution of different ultrasound systems for acoustic ONSD measurement.MethodsFirst, we calculated the theoretically lateral imaging resolution at increasing frequencies: 6.6, 10, and 15 MHz using two different ultrasound systems. Second, we created two phantoms consisting of copper wires or polyvinylchloride (PVC) strips and tested the best lateral resolution at different frequencies with the two ultrasound systems. Using the same ultrasound systems, we evaluated the anatomy of optic nerve at increasing transmission frequencies. Finally, the two probes were tested in two patients with different neurological conditions affected by an increase of ICP.ResultsTheoretical resolutions were .63, .43, and .41 mm, respectively, with a frequency of 6.6, 10, and 15 MHz. We found a similar lateral resolution in both phantoms: copper wire; .56 mm at 6.6 MHz, .46 mm at 10 MHz, and .44 mm at 15 MHz; and PVC strips .6 mm at 6.6 MHz, .47 mm at 10 MHz, and .40 mm at 15 MHz in accordance with experimental resolution. The ONSD thickening could be clearly displayed at frequencies higher than 7.5 MHz using the two linear probes and the two patients with an increase of ICP showed thickening of ONSD.ConclusionAccording to our study, both systems are suitable for ultrasound OSND measurement.© 2018 by the American Society of Neuroimaging.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.