-
- Tackeun Kim, O-Ki Kwon, Seung Pil Ban, Young Deok Kim, and Yu Deok Won.
- Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam, Korea; Department of Neurosurgery, Seoul National University College of Medicine, Seoul, Korea.
- World Neurosurg. 2019 May 1; 125: e289-e296.
BackgroundThe number of endovascular treatment procedures performed for cerebral aneurysms has markedly increased. However, little is known about the annual effective radiation dose to medical staff in neurointervention fields. We performed a retrospective observational study to investigate the real-time radiation dose to surgeons, nurses, anesthesiologists, and radiologic technologists during endovascular treatment of intracranial aneurysms.MethodsWe measured the real-time radiation doses for 2 weeks using standard and reinforced protection, during which 28 procedures were performed, including 23 coil embolizations for unruptured intracranial aneurysms. Four procedures were excluded because of an inadequately equipped sensor, which resulted in inappropriate data collection. The procedure time was defined from intubation to extubation. Five RaySafe i2 detectors were installed at the chest level of the operator, attending nurse, radiologic technologist, and anesthesiologist and just inside the front door of the hybrid operating room.ResultsThe median doses per session with standard protection to the operator, attending nurse, anesthesiologist, and radiologic technologist were 11.16, 2.60, 4.76, and 1.93 μSv, respectively. The dose to the operator, attending nurse, and anesthesiologist had decreased to 6.63, 0.39, and 1.52 μSv under reinforced protection, respectively. However, the session dose for the radiologic technologist had increased to 3.12 μSv.ConclusionsWe confirmed the differences in the amount of radiation exposure for different roles. An additional lead screen, which provided more effective protection on the operator side, was proved effective for attenuating radiation exposure during endovascular treatment. All personnel involved in the hybrid operating room were exposed to acceptable effective doses.Copyright © 2019 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.