-
- Charles-Henri Houzé-Cerfon, Vincent Bounes, Johanna Guemon, Thibault Le Gourrierec, and Thomas Geeraerts.
- Prehosp Emerg Care. 2019 Mar 1; 23 (2): 277-283.
ObjectiveIn patients with traumatic brain injury (TBI), early detection and subsequent prompt treatment of elevated intracranial pressure (ICP) is a challenge in the prehospital setting, because physical examination is limited in comatose patients and invasive device placement is not possible. The aim of this study was to evaluate the quality and feasibility of optic nerve sheath diameter (ONSD) measurements obtained during the prehospital management of patients with TBI.MethodsThis study was a prospective, observational study of 23 patients with moderate and severe TBI during prehospital medical care. The primary endpoint was the quality of ONSD measurements expressed as the percentage of ONSD validated by the experts. Secondary endpoints included the feasibility of ONSD measurements as the percentage of ONSD performed and assessment by operators of ease and duration to perform.ResultsUltrasound ONSD was performed in 19 (82%) patients and 80% of ONSD measurements were validated by the experts. The ONSD measurements were possible in 15 (79%) cases. The physicians have assessed the ease of use at 8 (interquartile range [IQR] = 2.5-8) on 10 for and the median time to obtain ONSD measurement was 4 min (IQR = 3-5). ONSD measurement was performed in 12 (63%) cases during the transport and in 7 (37%) cases on scene, with 58% (n = 7) and 71% (n = 5) validated ONSD, respectively. The success rate in the helicopter was 43% compared to 80% in the ambulance.ConclusionThis study shows that it is feasible to obtain high-quality ONSD measurements in the management of patients with TBI in a prehospital setting. A randomized study evaluating the usefulness of ONSD to guide management of TBI in the prehospital phase may be of great interest.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.