• Prehosp Emerg Care · Mar 2019

    Observational Study

    Can Altering Grip Technique and Bag Size Optimize Volume Delivered with Bag-Valve-Mask by Emergency Medical Service Providers?

    • Melissa Kroll, Jyoti Das, and Jeffrey Siegler.
    • Prehosp Emerg Care. 2019 Mar 1; 23 (2): 210-214.

    IntroductionEmergency Medical Services (EMS) professionals rely on the bag-valve-mask (BVM) to provide life-saving positive-pressure ventilation in the prehospital setting. Multiple emergency medicine and critical care studies have shown that lung-protective ventilation protocols reduce morbidity and mortality. A recent study has shown that the volumes typically delivered by EMS professionals with the adult BVM are often higher than recommended by lung-protective ventilation protocols. Our primary objective was to determine if a group of EMS professionals could reduce the volume delivered by adjusting the way the BVM was held. Secondary objectives included 1) if the adjusted grip allowed for volumes more consistent with lung-protection ventilation strategies and 2) comparing volumes to similar grip strategies used with a smaller BVM.MethodsA patient simulator of a head and thorax was used to record respiratory rate, tidal volume, peak pressure, and minute volume delivered by participants for 1 minute each across 6 different scenarios: 3 different grips (using the thumb and either 3 fingers, 2 fingers, or one finger) with 2 different sized BVMs (adult and pediatric). Trials were randomized by blindly selecting a paper with the scenario listed. A convenience sample of EMS providers was used based on EMS provider and research staff availability.ResultsWe enrolled 50 providers from a large, busy, urban hospital-based EMS agency a mean 8.60 (SD = 9.76) years of experience. Median volumes for each scenario were 836.0 mL, 834.5 mL, and 794 mL for the adult BMV (p = 0.003); and 576.0 mL, 571.5 mL, and 547.0 mL for the pediatric BVM (p < 0.001). Across all 3 grips, the pediatric BVM provided more breaths within the recommended volume range for a 70 kg patient (46.4% vs. 0.4%; p < 0.001) with only a 1.1% of breaths below the recommended tidal volume.ConclusionThe study suggests that it is possible to alter the volume provided by the BVM by altering the grip on the BVM. The tidal volumes recorded with the pediatric BVM were above recommended range in 2 of the 3 grips. The volumes of the pediatric BVM were overall more consistent with lung-protective ventilation volumes when compared to all 3 finger-grips of the adult BVM.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…