• J Laparoendosc Adv Surg Tech A · Jun 2017

    Lower Esophageal Sphincter Augmentation for Gastroesophageal Reflux Disease: The Safety of a Modern Implant.

    • C Daniel Smith, Robert A Ganz, John C Lipham, Reginald C Bell, and David W Rattner.
    • 1 Esophageal Institute of Atlanta , Atlanta, Georgia .
    • J Laparoendosc Adv Surg Tech A. 2017 Jun 1; 27 (6): 586-591.

    IntroductionUse of the magnetic sphincter augmentation device (MSAD) for gastroesophageal reflux disease (GERD) is increasing. As this innovative treatment for GERD gains widespread use and adoption, an assessment of its safety since U.S. market introduction is presented.MethodsEvents were collected from the Manufacturer and User Facility Device Experience (MAUDE) database, which reports events submitted to the Food and Drug Administration (FDA) of suspected device-associated deaths, serious injuries, and malfunctions. The reporting period was from March 22, 2012 (FDA approval) through May 31, 2016, and included only events occurring in the United States. Additional information was provided by the manufacturer, allowing calculation of implant rates and durations.ResultsAn estimated 3283 patients underwent magnetic sphincter augmentation (165 surgeons at 191 institutions). The median implant duration was 1.4 years, with 1016 patients implanted for at least 2 years. No deaths, life-threatening events, or device malfunctions were reported. The overall rate of device removal was 2.7% (89/3283). The most common reasons for device removal were dysphagia (52/89) and persistent reflux symptoms (19/89). Removal for erosion and migration was 0.15% (5/3283) and 0% (0/3283), respectively. There were no perforations. Of the device removals, 57.3% (51/89) occurred <1 year after implant, 30.3% (27/89) between 1 and 2 years, and 12.4% (11/89) >2 years after implant. The rate of device removal and erosion with an implant duration >2 years were 1.1% (11/1016) and 0.1% (1/1016), respectively. All device removals and erosions were managed nonemergently, with no complications or long-term consequences.ConclusionsDuring a 4-year period in more than 3000 patients, no unanticipated MSAD complications have emerged, and there is no data to suggest a trend of increased events over time. The presentation and management of device-related issues have been less complicated than revisions for laparoscopic fundoplication or other interventions for GERD. MSAD is considered safe for the widespread treatment of GERD.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.