Journal of neurosurgery · Feb 2020
Biomechanics of a novel reversibly expandable dynamic craniotomy bone flap fixation plate.
- Rohit Khanna, Lisa Ferrara, and Sohit Khanna.
- 1Neurosurgery Service, Halifax Health, Daytona Beach, Florida.
- J. Neurosurg. 2020 Feb 1; 132 (2): 560567560-567.
ObjectiveBiomechanical evaluation of a novel expandable cranial fixation plate was assessed in cadavers. The dynamic craniotomy procedure uses low-profile reversibly expandable plates that allow cranial decompression by providing for intracranial volume expansion without removal of the bone flap. The plates allow reversible outward movement of the bone flap upon an increase in intracranial pressure (ICP) and also retract the bone flap and prevent it from sinking inside the cranium once the ICP normalizes.MethodsA comparative evaluation of the extent of ICP control with an increase in intracranial volume between various bone flap fixation techniques was undertaken along with testing of the expandable plate compliance. Static compression tests of the plates were performed to assess bone flap fixation and prevention of sinking. Quasi-static shear tension testing of the plates was undertaken to test the tolerance of the plates for expansion. Fatigue shear tension evaluation of the plates was undertaken to assess tolerance for repetitive expansion and contraction.ResultsThe dynamic craniotomy provided superior control of ICP with an increase in intracranial volume compared to the hinged craniotomy and standard craniotomy techniques (p < 0.001). Static compression results revealed that the plates withstood bone flap sinkage with a mean peak load of 643.3 ± 26.1 N and a mean inward bone flap displacement of 1.92 ± 0.09 mm. Static shear tension results indicated that the plates could withstand a peak expansion of 71.6 mm. Dynamic shear tension testing of the plates with repetitive 15-mm outward expansion and retraction for a total of up to 500 cycles revealed no cracking and no failure points.ConclusionsThe reversibly expandable plates provide for a low-profile bone flap fixation with rigid restriction of bone flap sinking and also enable cranial decompression with a high tolerance for repetitive expansion and contraction.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.