• Anesthesiology · May 2019

    Extracorporeal Arteriovenous Ultrasound Measurement of Cardiac Output in Small Children.

    • Theodor S Sigurdsson, Anders Aronsson, and Lars Lindberg.
    • From the Department of Pediatric Anesthesiology and Intensive Care Medicine, Children's Hospital, University Hospital of Lund, Lund, Sweden (T.S.S., A.A., L.L.) the Department of Anesthesiology and Intensive Care Medicine, Landspítalinn, University Hospital of Iceland, Reykjavík, Iceland (T.S.S.).
    • Anesthesiology. 2019 May 1; 130 (5): 712-718.

    BackgroundTechnology for cardiac output (CO) and blood volume measurements has been developed based on blood dilution with a small bolus of physiologic body temperature saline, which, after transcardiopulmonary mixing, is detected with ultrasound sensors attached to an extracorporeal arteriovenous loop using existing central venous and peripheral arterial catheters. This study aims to compare the precision and agreement of this technology to measure cardiac output with a reference method, a perivascular flow probe placed around the aorta, in young children. The null hypothesis is that the methods are equivalent in precision, and there is no bias in the cardiac output measurements.MethodsForty-three children scheduled for cardiac surgery were included in this prospective single-center comparison study. After corrective cardiac surgery, five consecutive repeated cardiac output measurements were performed simultaneously by both methods.ResultsA total of 215 cardiac output measurements were compared in 43 children. The mean age of the children was 354 days (range, 30 to 1,303 days), and the mean weight was 7.1 kg (range, 2.7 to 13.6 kg). The precision assessed as two times the coefficient of error was 3.6% for the ultrasound method and 5.0% for the flow probe. Bias (mean COultrasound 1.28 l/min - mean COflow probe 1.20 l/min) was 0.08 l/min, limits of agreement was ±0.32 l/min, and the percentage error was 26.6%.ConclusionsThe technology to measure cardiac output with ultrasound detection of blood dilution after a bolus injection of saline yields comparable precision as cardiac output measurements by a periaortic flow probe. The difference in accuracy in the measured cardiac output between the methods can be explained by the coronary blood flow, which is excluded in the cardiac output measurements by the periaortic flow probe.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.