• Resuscitation · Jun 2019

    The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound.

    • Karine Badra, Alexandre Coutin, Robert Simard, Ruxandra Pinto, Jacques S Lee, and Jordan Chenkin.
    • Department of Emergency Medicine, St. Paul's Hospital, Vancouver, British Columbia, Canada. Electronic address: karine.badra@usherbrooke.ca.
    • Resuscitation. 2019 Jun 1; 139: 17-23.

    BackgroundManual pulse checks (MP) are an unreliable skill even in the hands of healthcare providers (HCPs). In the context of cardiac arrest, this may translate into inappropriate chest compressions when a pulse is present, or conversely omitting chest compressions when one is absent. To date, no study has assessed the use of B-mode ultrasound (US) for the detection of a carotid pulse. The primary objective of this study was to assess the time required to detect a carotid pulse in live subjects using US compared to the traditional palpation method.MethodsWe conducted a prospective randomized controlled crossover non-inferiority trial. HCPs attended a 15 minute focused US workshop on identification of the carotid pulse. Both pulse check methods were timed for each participant on two different subjects in random order. The primary outcome was time to carotid pulse detection in seconds (s). Secondary outcomes included confidence levels of pulse detection measured on a 100 mm visual analog scale (VAS) and rates of prolonged pulse checks (> 5 s or >10 s). The study was powered to determine whether US pulse checks were not slower than MP by greater than two seconds. The results are presented as the difference in means with a 90% two-sided confidence interval (CI).Results111 participants completed the study. Mean pulse detection times were 4.22 s (SD 3.26) by US compared to 4.71 s (SD 6.45) by MP with a mean difference in times of -0.49 s (90% CI: -1.77 to 0.39). There were no significant differences between US and MP in the rates of prolonged pulse checks of greater than 5 s (23% vs 19%, p = 0.45) or 10 s (9% vs 8%, p = 0.81). First attempt at detection of pulse checks was more successful in the US group (99.1% vs 85.6%, p = 0.0001). Prior to training, participants reported higher confidence using MP compared to US; 68 (IQR 48-83) vs 15 (IQR 8-42) mm (p < 0.001). Following the study, participants reported higher confidence levels using US than MP; 91 (IQR 82-97) vs 83 (IQR 72-94) mm (p < 0.001).ConclusionsCarotid pulse detection in live subjects was not slower using US as compared to palpation, and demonstrated higher first attempt success rate and less variability in measurement times. A brief teaching session was sufficient to improve confidence of carotid pulse identification even in those with no previous US training. The preliminary results from this study provide the groundwork for larger studies to evaluate this pulse check method for patients in cardiac arrest.Copyright © 2019 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…