• Journal of neurosurgery · Mar 2020

    Accuracy of frameless image-guided implantation of depth electrodes for intracranial epilepsy monitoring.

    • Robert E Gross, Edward K Sung, Patrick Mulligan, Nealen G Laxpati, Darlene A Mayo, and John D Rolston.
    • Departments of1Neurosurgery and.
    • J. Neurosurg. 2020 Mar 1; 132 (3): 681691681-691.

    ObjectiveVarious techniques are available for stereotactic implantation of depth electrodes for intracranial epilepsy monitoring. The goal of this study was to evaluate the accuracy and effectiveness of frameless MRI-guided depth electrode implantation.MethodsUsing a frameless MRI-guided stereotactic approach (Stealth), depth electrodes were implanted in patients via burr holes or craniotomy, mostly into the medial temporal lobe. In all cases in which it was possible, postoperative MR images were coregistered to planning MR images containing the marked targets for quantitative analysis of intended versus actual location of each electrode tip. In the subset of MR images done with sufficient resolution, qualitative assessment of anatomical accuracy was performed. Finally, the effectiveness of implanted electrodes for identifying seizure onset was retrospectively examined.ResultsSixty-eight patients underwent frameless implantation of 413 depth electrodes (96% to mesial temporal structures) via burr holes by one surgeon at 2 institutions. In 36 patients (203 electrodes) planning and postoperative MR images were available for quantitative analysis; an additional 8 procedures with 19 electrodes implanted via craniotomy for grid were also available for quantitative analysis. The median distance between intended target and actual tip location was 5.19 mm (mean 6.19 ± 4.13 mm, range < 2 mm-29.4 mm). Inaccuracy for transtemporal depths was greater along the electrode (i.e., deep), and posterior, whereas electrodes inserted via an occipital entry deviated radially. Failure to localize seizure onset did not result from implantation inaccuracy, although 2 of 62 patients (3.2%)-both with electrodes inserted occipitally-required reoperation. Complications were mostly transient, but resulted in long-term deficit in 2 of 68 patients (3%).ConclusionsDespite modest accuracy, frameless depth electrode implantation was sufficient for seizure localization in the medial temporal lobe when using the orthogonal approach, but may not be adequate for occipital trajectories.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…