• Eur J Anaesthesiol · Jun 2019

    Comparative Study Observational Study

    Accuracy of oscillometric noninvasive blood pressure compared with intra-arterial blood pressure in infants and small children during neurosurgical procedures: An observational study.

    • Agnes S Meidert, Martin Tholl, Tanija K Hüttl, Patricia Bernasconi, Aurelia Peraud, and Josef Briegel.
    • From the Department of Anaesthesiology (ASM, MT, TKH, PB, JB), the Department of Neurosurgery, University Hospital of Munich (LMU), Munich, Germany (AP), and the Department of Neurosurgery, University Hospital Ulmm, Ulm, Germany (AP).
    • Eur J Anaesthesiol. 2019 Jun 1; 36 (6): 400-405.

    BackgroundGeneral anaesthesia in children results in a significant decrease of arterial pressure. Hypotension in neonates and infants reduces cerebral perfusion; therefore, an accurate arterial pressure measurement is of utmost importance. Although arterial pressure measured via an arterial catheter is considered to be the gold standard, in most children undergoing anaesthesia, arterial pressure is monitored by an upper arm cuff using an oscillometric technique. Data on the accuracy of these devices in such young patients are rare.ObjectiveThe aim of this study was to assess the accuracy of oscillometric blood pressure measurement compared with intra-arterial measurement.DesignAn observational comparison study.SettingA single-centre study, conducted in a German university hospital from November 2015 to January 2018.PatientsTwenty-five children of 2 years old or less (median age 6 [IQR, 5 to 11]) months undergoing neurosurgical procedures requiring invasive arterial pressure determination.Main Outcome MeasuresArterial pressure was measured invasively and also oscillometrically by an upper arm cuff every 10 min. Simultaneously measured pairs of mean arterial pressures were analysed by the Bland-Altman method; the correlation coefficient, percentage error and concordance were calculated.ResultsData from 21 children were analysed. Mean, (standard deviation) and [range] of invasive and noninvasive mean arterial pressures were 54 (8) [30 to 94] and 57 (8) [40 to 108] mmHg, respectively. The overall bias between invasive and noninvasive arterial pressure was -3 (7) mmHg, with 95% limits of agreement from -17 to +10 mmHg. The correlation coefficient, percentage error and concordance were 0.65, 25% and 0.77, respectively. For hypotensive invasive arterial pressure values below 45 mmHg, the mean bias (invasive arterial pressure - noninvasive arterial pressure) was -9 (5) mmHg.ConclusionArterial pressure derived by the oscillometric device showed acceptable levels of agreement. However, during hypotension, a clinically relevant overestimation of arterial pressure occurred when measured by an upper arm cuff.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.