• J Neurosurg Anesthesiol · Jan 2020

    Comparative Study

    Cervical Spine Movement in a Cadaveric Model of Severe Spinal Instability: A Study Comparing Tracheal Intubation With 4 Different Laryngoscopes.

    • Jia W Romito, Christina A Riccio, Carlos A Bagley, Abu Minhajuddin, Catherine B Barden, Meghan M Michael, Ravi Bhoja, Brady L Mootz, Gary D Skrivanek, Kevin W Klein, and David L McDonagh.
    • Departments of Anesthesiology & Pain Management.
    • J Neurosurg Anesthesiol. 2020 Jan 1; 32 (1): 57-62.

    BackgroundThis study compared the Macintosh blade direct laryngoscope, Glidescope, C-Mac d-Blade, and McGrath MAC X-blade video laryngoscopes in 2 cadaveric models with severe cervical spinal instability. We hypothesized that the Glidescope video laryngoscope would allow for intubation with the least amount of cervical spine movement. Our secondary endpoints were glottic visualization and intubation success.MethodsIn total, 2 fresh cadavers underwent maximal surgical destabilization from the craniocervical junction to the cervicothoracic junction by a neurosurgical spine specialist, with subsequent neutral positioning of the heads with surgical head fixation devices. On each cadaver, 8 experienced anesthesiologists performed four intubations with the 4 laryngoscopes in random order. Lateral radiographic measurements determined vertebral displacement during intubation.ResultsCervical spine displacements were not significantly different amongst video laryngoscopes. Cormack-Lehane Grade 1 views were achieved with all attempts with each of the 3 video laryngoscopes; intubation attempts with the Macintosh blade achieved only grade 3 or grade 4 views. Intubation was successful every time with a video laryngoscope but only during 1 of 16 intubation attempts with the Macintosh blade.ConclusionsIn a cadaveric model with maximally destabilized cervical spines, cervical spine movement was observed during attempted laryngoscopy using each of 3 video laryngoscopes, although there was no significant difference between the laryngoscopes. Given cervical spine displacement occurred, these video laryngoscopes do not prevent cervical spine motion during laryngoscopy. However, with improved glottic visualization and intubation success, video laryngoscopes are superior to the Macintosh blade in both cervical spine safety and intubation efficacy in the model studied.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…