• Neurosurgery · Apr 2005

    Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system.

    • Lars-Owe D Koskinen and Magnus Olivecrona.
    • Department of Pharmacology and Clinical Neuroscience, Division of Neurosurgery, Umeå University Hospital, Umeå, Sweden. Lars-Owe.Koskinen@neuro.umu.se
    • Neurosurgery. 2005 Apr 1; 56 (4): 693-8; discussion 693-8.

    ObjectiveOur main objective was to study the reliability of the Codman MicroSensor (CMS), used for intracranial pressure (ICP) measurements, as it is used in a clinical setting. In particular, the drift from zero was studied.MethodsThe investigation is a prospective study of 128 patients with a need for neurointensive care who have been treated for various diseases. The patients received an intraparenchymal CMS device, and the zero drift was measured at explantation of the sensor. In another 22 patients, the ICP was recorded simultaneously from a ventriculostomy and a CMS, and the values were compared. The general data of complications and pitfalls are collected from close to 1000 CMS devices implanted.ResultsThe CMS was used, on average, 7.2 +/- 0.4 days per patient. The total time of ICP measurement was 20,040 hours, resulting in at least 7.2 x 10(7) measuring values displayed. The drift from zero was 0.9 +/- 0.2 mm Hg, and no correlation with duration of use was found (P = 0.9, r = 0.002). There was a good correlation between ICP measured by CMS and by ventriculostomy (P < 0.0001, r = 0.79). The average ICP measured with the ventriculostomy was 18.3 +/- 0.3 mm Hg, and with the CMS, it was 19.0 +/- 0.2 mm Hg. A few minor hematomas were identified, and no infections directly connected to the device were observed. Some pitfalls in handling and problems during magnetic resonance imaging investigations are discussed.ConclusionIn our hands, the CMS device is reliable and easy to use. The ICP recordings are stable over time, and there is only a minor zero drift. The device is today our standard method for ICP measurements.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…