Comparative Study
Ideal suture diameter is critical for consistent middle cerebral artery occlusion in mice.
- Kudret Türeyen, Raghu Vemuganti, Kurt A Sailor, and Robert J Dempsey.
- Department of Neurological Surgery, University of Wisconsin, Madison, Wisconsin, USA.
- Neurosurgery. 2005 Jan 1; 56 (1 Suppl): 196-200; discussion 196-200.
ObjectiveThe use of transgenic and knockout mice has led to a need for a consistent model of mouse transient focal cerebral ischemia. In a great majority of the published mouse middle cerebral artery (MCA) occlusion studies, the methods indicated the type of intraluminal suture used without indicating the actual suture diameter after modification. We attempted to determine the ideal suture diameter to produce consistent occlusion in the MCA of adult male C57BL/6 mice.MethodsSuture tips were coated to a depth 4 mm with glue, and 6-0 sutures of eight different, precisely measured diameters were produced. The coated 6-0 sutures in different diameters were introduced 10 mm into the internal carotid artery via the external carotid artery of the mice to produce MCA occlusion (n = 40; five animals for each diameter), and the mice (22-24 g) were transaortically perfused with saline. The base of the brain was exposed, and photographs of the vessels were obtained before and after transaortic injection of Evans blue dye to determine the consistency of MCA occlusion for each suture diameter. Cerebral blood flow was measured 10 minutes before occlusion and 20 minutes after reperfusion, and 2,3,5-triphenyltetrazolium chloride staining was performed to demonstrate the ischemic damage in additional animals with 110-microm (n = 5) and 180-microm (n = 8) diameter sutures.ResultsSutures measuring 170 microm and 180 microm in diameter consistently occluded the MCA of C57BL/6 mice. In addition, 2,3,5-triphenyltetrazolium chloride staining demonstrated consistent infarction with 180-microm diameter sutures. The infarct volume was 36.3 +/- 4.2 mm3.ConclusionSmall changes in the diameter of the occlusion suture tip affect consistency in the mouse MCA occlusion model.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.