• Respiratory care · Nov 2019

    Diagnostic Performance of Carbon Monoxide Testing by Pulse Oximetry in the Emergency Department.

    • Nuria Villalba, Zachary T Osborn, Pamela R Derickson, Chelsea T Manning, Robert R Herrington, David A Kaminsky, and Kalev Freeman.
    • Department of Surgery, Larner College of Medicine, University of Vermont, Burlington, Vermont.
    • Respir Care. 2019 Nov 1; 64 (11): 1351-1357.

    BackgroundCarbon monoxide (CO) exposure causes roughly 40,000 emergency department (ED) visits annually and is commonly misdiagnosed. Whereas the standard method of carboxyhemoglobin (HbCO) measurement utilizes blood gas analysis, a noninvasive, FDA-cleared alternative exists. We evaluated the performance of pulse oximetry (SpCO) for identification of CO exposure in ED patients.MethodsWe compared pulse oximetry to blood HbCO levels in a prospective observational study of adult and pediatric subjects recruited from the ED. Nurses screened a convenience sample of patients and referred those with SpCO ≥ 10% to research staff. Researchers also approached individuals who presented with signs and symptoms of CO toxicity. We determined diagnostic performance with a Bland-Altman analysis and calculated sensitivity and specificity for detection of elevated HbCO at thresholds of ≥ 10% and ≥ 15%. To optimize the potential sensitivity of SpCO for detection of CO toxicity, research technicians performed 3 SpCO readings within 5 min of the blood draw for laboratory measurement. A positive SpCO test was defined as any SpCO ≥ 10%.Results42,000 patients were screened, 212 were evaluated, and 126 subjects were enrolled. Median HbCO level was 6% (range 1.6-21.9%). Limits of agreement were -10.3% and 8.1%. Of 23 individuals with elevated HbCO ≥ 10%, 13 were not suspected based on clinical assessment. Critically elevated HbCO was present in 6 individuals. Based on our a priori threshold of 10% for a positive test, pulse oximetry identified 14 of 23 subjects with HbCO ≥ 10%, with a sensitivity of 61% (95% CI 39-80%) and a specificity of 86% (95% CI 78-92%), and 5 of 6 subjects with HbCO ≥ 15%, with a sensitivity of 83% (95% CI 36-100%) and a specificity of 81% (95% CI 73-87%).ConclusionsPulse oximetry underestimated HbCO and produced false negative results (ie, SpCO < 10% for all three measurements) in 17% of ED subjects with elevated HbCO ≥ 15%. Triage screening with pulse oximetry detected cases of elevated HbCO that were not suspected by the clinical provider.Copyright © 2019 by Daedalus Enterprises.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…