• Eur J Anaesthesiol · Aug 2018

    Comparative Study

    Level of agreement between laboratory and point-of-care prothrombin time in patients after stopping or continuation of acenocoumarol anticoagulation: A comparison of diagnostic accuracy.

    • Elisabeth A J de Vos, Yolien J Hagen, Michael I Meesters, Nada Osmanovic, Christa Boer, and Marcel A de Leeuw.
    • From the Department of Anesthesiology, VU University Medical Center, Institute for Cardiovascular Research, Amsterdam (EAJdV, YJH, MIM, CB, MAdL), Department of Anesthesiology (YJH, MAdL) and Department of Clinical Chemistry, Zaans Medical Center, Zaandam, The Netherlands (NO).
    • Eur J Anaesthesiol. 2018 Aug 1; 35 (8): 621-626.

    BackgroundProcedures requiring optimisation of the coagulation status of patients using vitamin K antagonists are frequently postponed due to the late availability of laboratory international normalised ratio (INR) test results. A point-of-care (POC) alternative may facilitate early decision-making in peri-operative patients.ObjectivesTo assess the level of agreement between the POC-INR and the laboratory INR in patients who continue or stop vitamin K antagonists to determine whether the POC test may be a good alternative to the laboratory INR.DesignStudy of diagnostic accuracy.SettingSingle-centre study at Zaans Medical Centre, The Netherlands.PatientsIncluded patients were scheduled for cardioversion (these continued taking vitamin K antagonists), or a surgical procedure (these stopped taking vitamin K antagonists).Main Outcome MeasuresThe level of agreement and clinical acceptability of the laboratory and POC-INR results, evaluated by Bland-Altman analysis and error grid analysis.ResultsThe surgical and cardioversion groups consisted of 47 and 46 patients, respectively. The bias in the INR in the surgical group was -0.12 ± 0.09 with limits of agreement of -0.29 to 0.05, whereas the cardioversion group showed a bias in the INR of -0.22 ± 0.36 with limits of agreement from -0.93 to 0.48. The percentage errors between methods in the surgical and cardioversion groups were 16 and 21%, respectively. Error grid analysis showed that the diagnostic accuracy of the POC prothrombin time is clinically acceptable as the difference did not lead to a different clinical decision in the surgical group with INR values less than 1.8.ConclusionThe current study shows a good level of agreement and clinical accuracy between the laboratory and POC-INR in patients who stopped anticoagulation intake for surgery. However, in patients who continued their anticoagulation therapy, the agreement between the two methods was less accurate.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…