-
- Sergey Sindeev, Sascha Prothmann, Sergey Frolov, Claus Zimmer, Dieter Liepsch, Philipp Berg, Jan Stefan Kirschke, and Benjamin Friedrich.
- Department of Biomedical Engineering, Tambov State Technical University, Tambov, Russia. Electronic address: ssindeev@yandex.ru.
- World Neurosurg. 2019 Feb 1; 122: e577-e583.
BackgroundFlow diverter stents have become a useful tool for treatment of complex intracranial aneurysms. A serious complication is incomplete wall apposition after flow diverter placement. The aim of this study was to present a comprehensive investigation of hemodynamic changes induced by incomplete expansion of a flow diverter.MethodsA case of a patient treated for an internal carotid artery aneurysm by flow diversion with incomplete wall apposition was virtually investigated. The effect of incomplete flow diverter expansion was studied using image-based blood flow simulations under physiologically relevant flow conditions based on patient-specific clinical data.ResultsThe numerical results revealed that incomplete expansion at the proximal end of the stent had minimal impact on the intra-aneurysmal blood flow alteration. A region of nonphysiologically high wall shear stress was observed near the contact area between the incompletely expanded proximal end of the flow diverter and the parent artery, which caused an intimal hyperplasia in this region. These simulation results were consistent with the real-life clinical course and outcome.ConclusionsThe results of this study can be considered during treatment planning of complex cases where the risk of incomplete flow diverter expansion exists. Further studies are required before results can also be used to support the decision process about antiplatelet therapy and additional interventions to improve wall apposition.Copyright © 2018 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.