-
- M Richter, H J Wilke, P Kluger, S Neller, L Claes, and W Puhl.
- Department of Orthopaedics and SCI, University of Ulm, Germany. marcus.richter@medizin.uni-ulm.de
- Eur Spine J. 2000 Oct 1; 9 (5): 417-25.
AbstractPosterior instrumentation of the occipito-cervical spine has become an established procedure in a variety of indications. The use of rod-screw systems improved posterior instrumentation as it allows optimal screw positioning adapted to the individual anatomic situation. However, there are still some drawbacks concerning the different implant designs. Therefore, a new modular rod-screw implant system has been developed to overcome some of the drawbacks of established systems. The aim of this study was to evaluate whether posterior internal fixation of the occipito-cervical spine with the new implant system improves primary biomechanical stability. Three different internal fixation systems were compared in this study: the CerviFix System, the Olerud Cervical Rod Spinal System and the newly developed Neon Occipito Cervical System. Eight human cervical spine CO/C5 specimens were instrumented from C0 to C4 with occipital fixation, transarticular screws in C1/C2 and lateral mass or pedicle screws in C3 and C4. The specimens were tested in flexion/extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. After testing the intact spine, the different instrumentations were tested after destabilising C0/C2 and C3/C4. Primary stability was significantly increased, in all load cases, with the new modular implant system compared to the other implant systems. Pedicle screw instrumentation tended to be more stable compared to lateral mass screws; nevertheless, significant differences were observed only for lateral bending. As the experimental design precluded any cyclic testing, the data represent only the primary stability of the implants. In summary, this study showed that posterior instrumentation of the cervical spine using the new Neon Occipito Cervical System improves primary biomechanical stability compared to the CerviFix System and the Olerud Cervical Rod Spinal System.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.