Paediatric anaesthesia · Aug 2019
Clinical TrialIntra-operative temperature monitoring with cutaneous zero-heat- flux-thermometry in comparison with oesophageal temperature: A prospective study in the paediatric population.
- Hugo Carvalho, Nadia Najafi, and Jan Poelaert.
- Department of Anesthesiology and Perioperative Medicine, Universitair Ziekenhuis Brussel (UZBrussel)-Vrije Universiteit Brussel (VUB), Brussels, Belgium.
- Paediatr Anaesth. 2019 Aug 1; 29 (8): 865-871.
BackgroundMaintenance of thermal homeostasis is of crucial importance in the anesthetized pediatric patient. Gold-standard methods for central core temperature measurement are however inappropriately invasive and impractical in daily practice. The SpotOn sensor uses zero-heat-flux thermometry technology and claims to bypass the invasiveness of classical methods and still accurately display central core temperatures. Up to date no formal analysis of this method in children has taken place.AimsThe primary objective was to assess the accuracy in comparison with esophageal temperature; the secondary objective concerned the safety of the SpotOn sensor in the pediatric patients.MethodsFifty-four children aged 1-12 years with an American Society of Anesthesiology classification I or II scheduled to undergo elective surgical procedures under general anesthesia for a minimum of 30 minutes were included. Exclusion criteria included: fragile forehead skin, procedures impeding proper SpotOn placement, thoracoscopic or gastroesophageal procedures, coagulopathy, hemodynamic instability, or vasoactive medication use. After sevoflurane induction, an esophageal temperature probe was placed in the lower third of the esophagus, and a SpotOn sensor on the lateral forehead. Temperatures were recorded in pairs per 1 minute intervals. Temperatures were subjected to bias analysis with 0.5°C as the a priori established clinical significance cutoff.ResultsBland-Altman analysis revealed the two methods differed on average 0.14°C (95% limits of agreement: -0.39 to 0.66), with 89.5% of the differences being under 0.5°C. No significant differences could be found between the two methods for the established 0.5°C cutoff. Linear regression analysis determined the following linear regression equation: 0.837x + 5.86 (R2 = 0.738). Lin's concordance correlation coefficient of 0.83 (95% CI: 0.81-0.84). No complications were observed with the use of the SpotOn sensor.ConclusionSpotOn revealed itself as accurate as an esophageal temperature probe when estimating central core temperatures under ideal conditions and over a narrow range of temperatures. No adverse effects were observed with the use of the SpotOn sensor.© 2019 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.