-
- M Bollinger, C Keller, C Theis, and S G Russo.
- Klinik für Anästhesiologie, Helios Universitätsklinikum Wuppertal, Universität Witten/Herdecke, Heusnerstraße 40, 42283, Wuppertal, Deutschland. matthias.bollinger@helios-gesundheit.de.
- Anaesthesist. 2019 Jun 1; 68 (6): 384-388.
BackgroundInfusion sets with precision flow regulators are frequently used in children undergoing surgery in order to control the perioperative administration of fluids. There are no data about the safety and accuracy of these infusion sets. A study was therefore conducted to compare adjusted and actual flow rates of three different infusion sets with precision flow regulators under standardized conditions.MethodsThe study evaluated three different infusion sets with precision flow regulators each at two different static levels. The actual flow rates of 5 infusions were recorded each time for adjusted flow rates of 50 ml/h, 100 ml/h, 150 ml/h, 200 ml/h and 250 ml/h over 1 h. Statistical analysis was performed with Excel (Excel, Microsoft Corporation, Redmond, WA, USA) and SOFA (Paton-Simpson and Associates Ltd., USA). The results are presented as means (standard deviation).ResultsFor the adjusted flow rates of 50, 100, 150, 200 and 250 ml/h, actual flow rates were 107 (5.3), 174.8 (6.5), 255.8 (10.2), 312.4 (15.7) and 362.6 (20.2) ml/h for the Frekadrop® infusion set at a static level of 128 cm and 83.8 (4.4), 147.8 (5.5), 197 (12.4), 257.2 (4.97) and 311.6 (17.9) ml/h at a static level of 100 cm, respectively. For the Exadrop® infusion set actual flow rates were 88.6 (6.9), 131.2 (14.1), 224.4 (14.1), 296.6 (27.6) and 330.4 (22.4) ml/h at a static level of 128 cm and 54 (4), 82.4 (10.2), 138.8 (15.7), 209.4 (36.8) and 249 (12) ml/h at a static level of 76 cm, respectively. For the D-Flo infusion set actual flow rates were 95.6 (2.8), 167.6 (29), 217.8 (9.9), 281.6 (10.6) and 396.8 (37.5) ml/h at a static level of 128 cm and 69.2 (4.4), 110.2 (12.6), 169.2 (6), 205.2 (14) and 243 (15.9) ml/h at a static level of 80 cm, respectively.ConclusionThe actual flow rates differed considerably from the adjusted flow rates in the evaluated infusion sets. The flow rates substantially depended on the static level of the infusion. First and foremost, regulation of the administered infusion volume does not seem to be reliable when using an infusion set with a precision flow regulator.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.