- Anand D Gopal, Vinay K Rathi, Christopher C Teng, Lucian Del Priore, and Joseph S Ross.
- Yale University School of Medicine, New Haven, Connecticut; Department of Ophthalmology and Visual Science, Yale University School of Medicine, New Haven, Connecticut.
- Ophthalmology. 2017 Aug 1; 124 (8): 1237-1246.
PurposeTo characterize the frequency, nature, and regulatory mechanisms by which ophthalmic devices are iteratively modified after initial Food and Drug Administration (FDA) Premarket Approval (PMA).DesignRetrospective cross-sectional analysis using publicly available FDA data.ParticipantsOphthalmic devices initially approved via the FDA's PMA pathway between January 1, 1979 and December 31, 2015.MethodsWe used the FDA's PMA Database to identify and characterize initial approvals and subsequent postmarket modifications to Class III ophthalmic devices. The FDA Recalls Database was used to identify associated safety events.Main Outcome MeasuresMedian iterated life span (timespan across which modifications occurred after initial PMA) and median number of supplements approved per device, by device type, and overall, stratified by regulatory pathway and modification type.ResultsBetween 1979 and 2015, the FDA approved 168 original ophthalmic devices via the PMA pathway and 2813 subsequent modifications. More than one third (n = 64; 38%) of original approvals were intraocular lenses. Overall, devices underwent a median of 11 postmarket modifications (interquartile range [IQR], 3-24.8) across a median 10.0-year iterated life span (IQR, 4.1-16.7). The majority of devices (n = 144; 86%) underwent more than 1 postapproval modification, including more than 1 design modification (n = 84; 50%). The median number of changes altering device design or labeling was 3.5 (IQR, 1-9). Although manufacturing alterations (n = 834 of 2813; 30%) were the most frequent type of revision, changes involving device design (n = 667; 24%) and labeling (n = 417; 15%) were common. Recalled devices underwent more frequent postapproval modifications per year (median, 1.4; IQR, 0.7-2.3; mean, 1.5; 95% confidence interval, 1.1-1.9) in the period preceding recall than did nonrecalled devices (median, 0.5; IQR, 0.2-1.1; mean, 0.8; 95% confidence interval, 0.7-1.0) across their market approval period (P < 0.001).ConclusionsMost ophthalmic devices approved via the FDA's PMA pathway have undergone extensive revisions, including serial design and labeling changes, since their initial approvals, often without supporting clinical data. Ophthalmologists should take into consideration that cumulative revisions may render the clinical evidence that supported an original FDA approval less relevant to newer device models.Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.