• Can J Anaesth · Jul 2019

    Investigation into spinal anesthetic failure with hyperbaric bupivacaine: the role of cold exposure on bupivacaine degradation.

    • Ellen K Wasan, Calen Sacevich, Anas El-Aneed, Munawar Mohammed, Jaweria Syeda, Erin Neville, Tatiana Orlowski, David Campbell, and Jonathan Gamble.
    • College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, SK, Canada. ellen.wasan@usask.ca.
    • Can J Anaesth. 2019 Jul 1; 66 (7): 803-812.

    PurposeHyperbaric bupivacaine (0.75% in dextrose) is used for spinal obstetric anesthesia. Occasional clusters of anesthetic failures occur in this setting, not readily attributable to clinical factors. We hypothesized that cold temperature exposure is related to bupivacaine instability.MethodsAn electronic survey was distributed to Canadian anesthesiologists to determine consistencies in spinal anesthesia practice, and to invite submission of failed bupivacaine samples for analysis. Another survey for hospital pharmacists focused on bupivacaine logistics. Ultraviolet (UV) spectrometry, differential scanning calorimetry, and high performance liquid chromatography were used to evaluate the effect of temperature on bupivacaine chemical stability. Mass spectrometry (MS) was used to observe bupivacaine and dextrose degradation in laboratory samples of hyperbaric 0.75% bupivacaine in dextrose. Hyperbaric bupivacaine that failed to produce adequate anesthesia in labour and delivery patients was subject to tandem MS/MS analysis on commonly observed ions to look for ion patterns consistent with bupivacaine degradation products and to compare with laboratory samples subjected to cold temperatures.ResultsCanadian obstetric anesthesiologists report similar practices and use hyperbaric bupivacaine for spinal anesthesia. Pharmacists surveyed indicated facility storage at room temperature but variable temperatures during shipping. No standard procedure for failure reporting was identified. Analysis of bupivacaine showed a slight decrease in bupivacaine concentration or UV spectral changes after incubation at temperatures ≤ 4°C. Mass spectrometric analysis of hyperbaric bupivacaine from failed spinal anesthesia cases showed complex and inconsistent patterns of ion formation, and different from the ion patterns observed for cooled vs uncooled bupivacaine solutions. Temperature-related changes were noted for dextrose in cooled samples in which dextrose-related ions were formed.ConclusionsCanadian clinical practice and handling of hyperbaric bupivacaine is consistent. Most respondents indicated an interest in a formal reporting and collection process. Cold exposure did not degrade bupivacaine. A complex and possibly inconsistent reaction involving dextrose was identified that requires further analysis of a larger sample size to elucidate the mechanisms.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.