-
- Pantelis Kalaitzidis, Stefan Orwat, Aleksander Kempny, Radke Robert, Brigitte Peters, Samir Sarikouch, Philipp Beerbaum, Helmut Baumgartner, Gerhard-Paul Diller, and Competence Network for Congenital Heart Defects, DZHK (German Center for Cardiovascular Research).
- Division of Adult Congenital and Valvular Heart Disease, Department of Cardiovascular Medicine, University Hospital Muenster, Muenster, Germany.
- Int. J. Cardiol. 2018 Aug 1; 264: 53-57.
BackgroundElectrical dyssynchrony and prolonged QRS duration are common in patients with repaired tetralogy of Fallot (ToF). It has been linked to increased risk of sudden cardiac death and right ventricular (RV) dysfunction. We investigated myocardial dyssynchrony using cardiac magnetic resonance imaging (CMR) and feature tracking analysis (FT) in this setting and compared it to myocardial deformation, conventional parameters of ventricular dysfunction and clinical parameters.Methods And ResultsPatients underwent standardized CMR investigations as part of a nationwide study. We prospectively assessed myocardial deformation and analysed regional wall motion abnormalities of the RV and the left ventricle (LV) using CMR-FT. The main measure of dyssynchrony was the maximal time difference (wall motion delay) of the regional strain as a parameter of mechanical biventricular dyssynchrony. In addition, clinical parameters and measures of cardiopulmonary exercise capacity were available. Overall 345 patients were included. Parameters of biventricular wall motion delay correlated significantly with global FT-strain parameters (p < 0.0001 for all imaging planes assessed). Furthermore, we found a significant correlation between circumferential RV motion delay and QRS duration (p = 0.006). Higher LV and RV wall motion delay parameters were also associated with lower peak oxygen consumption (p < 0.05) and a worse LV and RV ejection fraction (p < 0.02).ConclusionsAssessment of mechanical dyssynchrony is feasible using CMR-FT in ToF patients. Parameters of mechanical dyssynchrony correlate with electrical dyssynchrony, biventricular function and objective exercise capacity in this setting. Due to the weak degree of correlation, however, the clinical significance of these findings remains to be clarified by further studies.Copyright © 2018 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.