• Paediatric anaesthesia · Aug 2019

    Trans- tracheal jet oxygenation: Comparing the efficacy and safety of 2 self- made Y connector devices with the ENK oxygen flow modulator™ in an infant animal model.

    • Lim Evangeline H L EHL 0000-0002-6051-2302 Department of Paediatric Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore., Angela Y J Tan, David D W Sng, Seyed Ehsan Saffari, and Tan Josephine S K JSK Department of Paediatric Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore..
    • Department of Paediatric Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore.
    • Paediatr Anaesth. 2019 Aug 1; 29 (8): 799-807.

    BackgroundSelf-made Y-connector jet-oxygenation devices with wide-bore expiratory port have been described but not evaluated in infant models. Little is known about the effect of oxygen flow rates on jet oxygenation via transtracheal cannula.AimsThe aim of this study was to compare two self-made Y-connector jet-oxygenation devices against the ENK oxygen flow modulator™, and the effects of three different oxygen flow rates based on body weight, in both unobstructed and obstructed airways, on the time to re-oxygenate in a rabbit infant model. The aim was also to assess the effectiveness of an oxygen flow rate of 1 L/min, for re-oxygenation using ENK oxygen flow modulator™.MethodsNine rabbits were grouped in threes: Group 1 had a Y-connector attached to an intravenous infusion tubing, Group 2 the same Y-connector attached to a perfusion oxygenator tubing and Group 3, ENK oxygen flow modulator™. From oxygen saturations of 75%, the rabbits were jet oxygenated using their assigned device for 10 minutes at each flow rate of 1 L/kg/min, 1.5 L/kg/min and 2 L/kg/min with their airways unobstructed and later, obstructed. Group 3 had additional experiments involving an absolute oxygen flow rate of 1 L/min.ResultsAll devices resulted in rapid re-oxygenation within 40 seconds at flow rates of 1 L/kg/min. Oxygen flow rates beyond 1 L/kg/min in obstructed airways resulted in high airway pressures. All rabbits in Group 3 with obstructed airways died from barotrauma when jet oxygenated at a flow rate of 1.5 L/kg/min. When an oxygen flow rate of 1 L/min was used in Group 3, there was a failure to re-oxygenate to SpO2 90% within 120 seconds in some rabbits.ConclusionOur animal model results suggest that self-made Y-connector jet-oxygenation devices with wide-bore expiratory port are efficacious and perhaps safer than ENK oxygen flow modulator™ in obstructed airways, and jet oxygenation with minimal oxygen flow rates starting at 1 L/kg/min or (age [years] + 4) L/min, whichever lower, should be considered.© 2019 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…