Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants.
- D Pienkowski, G C Stephens, T M Doers, and D M Hamilton.
- Division of Orthopaedic Surgery, University of Kentucky, Lexington, USA. pienkow@pop.uky.edu
- Spine. 1998 Apr 1; 23 (7): 782-8.
Study DesignThis was a prospective in vitro study comparing titanium alloy and stainless steel alloy in transpedicular spine implants from two different manufactures.ObjectiveTo compare the multicycle mechanical performance of these two alloys, used in each of two different implant designs.Summary Of Background DataTranspedicular spine implants primarily have been manufactured from stainless steel, but titanium alloy offers imaging advantages. However, the notch sensitivity of titanium alloy has caused concern regarding how implants made from this material will compare in stiffness and fatigue life with implants made from stainless steel.MethodsTwenty-four implants (two alloys, two designs, six implants per group) were mounted in machined polyethylene wafers and repetitively loaded (up to 1 million cycles) from 80 N to 800 N using a 5-Hertz sinusoidal waveform. Load and displacement data were automatically and periodically sampled throughout the entire test.ResultsImplant stiffness increased with cycle load number, reached a steady state, then declined just before fatigue failure. Stiffness varied less in titanium transpedicular spine implants than in their stainless counterparts. All stainless steel implant types were stiffer (steady-state value, P < 0.0001) than their titanium alloy counterparts. One titanium implant design failed with fewer (P < 0.05) load cycles than its stainless steel counterpart, whereas a stainless steel implant of another design failed with fewer (P < 0.002) load cycles than its titanium counterpart. Overall, fatigue life, i.e., the total number of load cycles until failure, was related to implant type (P < 0.0001), but not to implant material.ConclusionsA transpedicular spine implant's fatigue lifetime depends on both the design and the material and cannot be judged on material alone. Stainless steel implants are stiffer than titanium alloy implants of equal design and size; however, for those designs in which the fatigue life of the titanium alloy version is superior, enlargement of the implant's components can compensate for titanium's lower modulus of elasticity and result in an implant equally stiff as its stainless steel counterpart. Such an implant made from titanium alloy would then be clinically preferable because of titanium's previously reported imaging advantages.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.