- Aaron C Cooper, Amy R Commers, Marsha Finkelstein, Polina G Lipnik, Lisa M Tollefson, Roger A Wilcox, and David S Hoff.
- Department of Pharmacy, Children's Hospitals and Clinics of Minnesota, Minneapolis, Minnesota 55404, USA. aaron.cooper@childrensmn.org
- Pharmacotherapy. 2011 Jul 1; 31 (7): 649-57.
Study ObjectiveTo characterize the extent that serum gentamicin concentrations are associated with hearing loss indicated by otoacoustic emission (OAE) screen failure in critically ill neonates receiving gentamicin in accordance with a high-dose, extended-interval dosing protocol.DesignRetrospective medical record review.SettingTwo neonatal intensive care units in a pediatric tertiary care system.PatientsSequential sample of 528 critically ill neonates who were admitted between February 2003 and January 2008 and who received a gentamicin pharmacokinetic consultation during the first week of life and an OAE hearing screen before hospital discharge. Neonates were stratified into two groups: very low birth weight (VLBW [≤ 1500 g]) and non-VLBW (> 1500 g).Measurements And Main ResultsGentamicin was dosed intravenously to achieve a target calculated gentamicin peak serum concentration (C(max)) of 7-10 μg/ml and a target trough serum concentration (C(min)) of less than 2 μg/ml. The dosage administered was 4 mg/kg/dose every 48 hours if the neonate's birth weight was less than 1250 g or if the neonate was receiving indomethacin. Otherwise, the dosing interval was every 24 hours. Initial OAE screen results were obtained from the medical records, and follow-up results were collected for neonates who failed the initial OAE screen. The overall rate of OAE screen failure was 13.1% (69/528 patients). The rate of OAE screen failure was 34.1% (29/85 patients) in the VLBW neonates, which was significantly higher than the failure rate in non-VLBW neonates (9.0% [40/443 patients], p=0.001). Multivariate analysis of non-VLBW neonates determined that each 1-μg/ml increase in gentamicin C(max) was associated with an increased risk of OAE screen failure (odds ratio [OR] 1.4, 95% confidence interval (CI) 1.1-1.7, p=0.003). Further, the non-VLBW neonate subpopulation had an increased rate of OAE screen failure if the gentamicin C(max) exceeded 10 μg/ml (OR 2.2, 95% CI 1.1-4.2, p=0.022) compared with neonates whose C(max) was 10 μg/ml or lower. No association between serum gentamicin concentration and OAE screen failure could be determined among the VLBW neonates.ConclusionNeonates weighing more than 1500 g at birth and whose gentamicin C(max) exceeded 10 μg/ml were at an increased risk for OAE screen failure. Monitoring and maintaining gentamicin C(max) at or below 10 μg/ml may minimize hearing impairment; however, further studies are necessary.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.