Observational Study
Validation of 3-minute diagnostic interview for CAM-defined Delirium to detect postoperative delirium in the recovery room: A prospective diagnostic study.
- Maria Olbert, Sophie Eckert, Rudolf Mörgeli, Jochen Kruppa, and Claudia D Spies.
- From the Department of Anesthesiology and Operative Intensive Care Medicine (MO, SE, RM, CDS) and Institute of Biometry and Clinical Epidemiology (JK), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health; Berlin Institute of Health (BIH), Berlin, Germany (MO, JK).
- Eur J Anaesthesiol. 2019 Sep 1; 36 (9): 683-687.
BackgroundRecent guidelines on postoperative delirium (POD) recommend POD screening in all patients, using a validated tool, starting in the recovery room. An operationalisation of the Confusion Assessment Method (CAM) criteria, the 3-Minute Diagnostic Interview for CAM-defined Delirium (3D-CAM), has been developed for use in general medical units.ObjectivesThe aim of this study was to evaluate 3D-CAM performance in an adult patient population to detect POD in the recovery room.DesignA prospective diagnostic study.SettingRecovery room of a tertiary care university hospital in Berlin, Germany, in 2017.PatientsPatients at least 18 years of age undergoing elective surgery.Main Outcome MeasuresPatients were subjected to evaluation by blinded investigators using the 3D-CAM and the Diagnostic and Statistical Manual of Mental Disorders 5 (DSM-5, reference standard). Sensitivity, specificity and positive predictive value (PPV) and negative predictive value (NPV) were analysed for 3D-CAM, in addition to test-retest and inter-rater reliability analyses.ResultsSixteen out of 176 patients (9.1%) developed POD. The 3D-CAM demonstrated strong test performance (specificity 0.88, sensitivity 1.0, area under the curve 0.94, PPV 0.44 and NPV 1.0), with a test-retest reliability of 90% (n = 10) and inter-rater reliability of 80% (n = 10).ConclusionIn this diagnostic study, 3D-CAM showed strong performance for detection of POD in the recovery room. Due to the low training requirements, fast application and high sensitivity, it might be particularly appropriate for clinical staff with limited experience in the assessment of POD.Trial RegistrationClinicalTrials.gov Identifier: NCT02992717.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.