• Injury · Nov 2019

    Non-union in lateral locked plating for distal femoral fractures: A systematic review.

    • Michael Tianfeng Wang, An Vincent V G VVG Department of Surgery, Royal Prince Alfred Hospital, Australia; Faculty of Medicine and Health, Sydney University, New South Wales, Australia. Electron, and Brahman Shankar Sivakumar.
    • Department of Surgery, Austin Health, Heidelberg, Victoria, Australia; Faculty of Medicine, Nursing and Health Sciences, Monash University, Victoria, Australia. Electronic address: TMichaelWang@gmail.com.
    • Injury. 2019 Nov 1; 50 (11): 1790-1794.

    IntroductionThis study aims to identify patient and intra-operative factors that contribute to non-union in locked lateral plating for distal femoral fractures.MethodsSystematic searches of English-language articles in Ovid Medline, PubMed, Embase, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews were undertaken in February 2018 according to the PRISMA guidelines. The search terms were (fracture or fracture*) AND (distal femur or distal femoral) AND (malunion or non-union). Eligible studies published at any time reported non-union rates and compared patient and intraoperative factors in patients who underwent locked lateral plating for traumatic distal femoral fractures. The quality of included papers was assessed using The Journal of Bone and Joint Surgery levels of evidence (Wright et al., 2003), and further appraised using the Downs and Black score (Downs and Black, 1998).ResultsEight studies investigating 1380 distal femoral fractures were found to satisfy the inclusion and exclusion criteria. These studies analysed a variety of patient and intra-operative factors that may contribute to non-union. These include high BMI, open fracture, comminution, fracture infection, stainless steel plate material, shorter working length, open reduction and internal fixation when compared with minimally invasive plate osteosynthesis, high construct rigidity scores and purely locking screw constructs.ConclusionThis review has identified multiple factors which potentially contribute to non-union including stainless steel plate material, high construct rigidity scores and purely locking screw constructs. These findings may reflect that overly rigid plating constructs can contribute to non-union. However, they should be taken in the context of heterogeneity amongst included studies, with further research necessary to support these findings.Copyright © 2019 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…