Heart, lung & circulation · Mar 2015
The Australian and New Zealand cardiac pacemaker and implantable cardioverter-defibrillator survey: calendar year 2013.
- Harry G Mond and Ian Crozier.
- Adjunct Associate Professor, Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia. Electronic address: hmond@bigpond.net.au.
- Heart Lung Circ. 2015 Mar 1; 24 (3): 291-7.
BackgroundA pacemaker (PM) and implantable cardioverter-defibrillator (ICD) survey was undertaken in Australia and New Zealand for calendar year 2013.Results And ConclusionsFor 2013, PMs sold as new implants in Australia was 15,203 (12,523 in 2009) and implanted in New Zealand were 1,641 (1,277 in 2009). The number of new PM implants per million population 652 for Australia (565 were in 2009) and 367 for New Zealand (299 in 2009). Although PM replacements rose in New Zealand, there was a fall in Australia as a result of improved power source service life. Pulse generator types sold in Australia were predominantly dual chamber 74% (71% in 2009) and implanted in New Zealand 59% (54% in 2009). There were 661 biventricular PMs implanted in Australia (446 in 2009) and 83 in New Zealand (45 in 2009). Transvenous pacing leads were overwhelmingly bipolar with preferences for active fixation leads, although, since 2009, there has been a minor resurgence in Australia of passive fixation lead usage in the atrium from 20 to ∼24%. There was also a marked increase in the ICD implants with 3904 new implants in Australia (3555 in 2009) and 423 in New Zealand (329 in 2009). The new ICD implants per million population were 167 for Australia (160 in 2009) and 95 for New Zealand (77 in 2009). Biventricular ICD implants increased significantly in both Australia (2211) and New Zealand (118).Published by Elsevier B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.