• Resuscitation · Oct 2019

    Review

    Novel technologies for heart rate assessment during neonatal resuscitation at birth - A systematic review.

    • Peter A Johnson, Po-Yin Cheung, Tze-Fun Lee, Megan O'Reilly, and Georg M Schmölzer.
    • Centre for the Studies of Asphyxia and Resuscitation, Neonatal Research Unit, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.
    • Resuscitation. 2019 Oct 1; 143: 196-207.

    Background6.5-9 million newborns worldwide require resuscitation at birth annually. During neonatal resuscitation, inaccurate or slow heart rate (HR) assessments may significantly increase risk of infant mortality or morbidity. Therefore fast, accurate, and effective HR assessment tools are critical for neonatal resuscitation.ObjectiveTo systematically review the literature about accuracy, latency, and efficacy of technologies for HR assessment during neonatal resuscitation.MethodsAdhering to PRISMA guidelines, PubMed, EMBASE, and Google Scholar databases were systematically searched to identify studies related to technologies for HR assessment, which could be used to guide neonatal resuscitation.ResultsForty-six studies evaluating HR assessment technologies for neonatal resuscitation were identified. In total, 16 studies (3/16 randomized trials and 13/16 observational studies) compared two or more HR assessment technologies to measure accuracy, latency, and efficacy. Of the trials, 1/3 had a low risk of bias while 2/3 had high risks. All observational studies had high risks of bias. Most studies considered infants not requiring resuscitation, constituting indirect evidence and lower certainty in the context of neonatal resuscitation. Two trials reported faster times to HR assessment using electrocardiogram with a mean(SD) 66(20) versus 114(39) s and a median(IQR) 24(19-39) versus 48(36-69) s (both p < 0.001), compared to pulse oximetry.ConclusionWhile electrocardiography is faster to assess HR at birth and more reliable to detect HR changes compared to other recommended technologies, practice should not exclusively rely on ECG. While novel technologies could support HR assessment, no studies validate their clinical efficacy during neonatal resuscitation.Copyright © 2019 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…