• J Clin Monit Comput · Aug 2020

    Comparative Study

    A comparison of controlled ventilation with a noninvasive ventilator versus traditional mask ventilation.

    • Mike Fogarty, Kai Kuck, Joseph Orr, and Derek Sakata.
    • Departments of Anesthesiology and Bioengineering, University of Utah School of Medicine, 30 North 1900 East, Room 3C444, Salt Lake City, UT, 84132, USA. m.fogarty@utah.edu.
    • J Clin Monit Comput. 2020 Aug 1; 34 (4): 771-777.

    AbstractAfter induction, but before intubation, many general anesthesia patients are manually bag-mask ventilated. The objective of this study was to determine the efficacy of bag-mask ventilation (MkV) of an anesthetized patient versus mask ventilation using a noninvasive ventilator (NIV). We hypothesized that feedback-controlled, mask ventilation via NIV is more efficacious and safer. This critical short period of time in the operating room was chosen to compare MkV versus NIV. 30 ASA I-III patients, aged 18-74, presenting for elective surgery under general anesthesia were enrolled in the study. Patients were ventilated first with MkV and then with NIV. One minute of ventilation data was collected for each method. Respiratory inductance plethysmography (RIP) bands around the chest and abdomen were used to measure tidal volumes and breath rates for each method of ventilation. The NIV was set to deliver 10 breaths per minute with 12 cmH2O of pressure support. A non-inferiority test was used to compare MkV and NIV. MkV breaths had an average of 13 breaths and tidal volume of 364 mL (SD 145 mL). NIV resulted in an average of 10 breaths and tidal volume of 552 mL, i.e., 188 mL more than MkV (lower bound of the 95% confidence interval equal to 120 mL). The hypothesis of non-inferiority at the - 100 mL level and the superiority hypothesis at the + 100 mL level was accepted. NIV also resulted in much more consistent ventilation rates (zero variation since it is controlled by the ventilator) when compared to manual ventilation while maintaining safe airway pressures (8 cmH2O EPAP and 20 cmH2O IPAP). Feedback controlled mask ventilation via a NIV is a viable alternative to MkV. It can deliver more optimal tidal volumes with the operator utilizing only one hand. The airway pressures are fixed at safe limits during a period where the goal is to reach a maximal level of oxygenation prior to intubation. Over-ventilation or over-pressurization of the airway is not a concern with NIV since the pressures are maintained well within safe thresholds to avoid injury.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.